Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Water Chiller WSC100
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Chiller Shutdown
Seasonal Servicing
Is the chiller subject to freezing temperatures?
If yes, drain the condenser and chiller of all water.
Did you use dry air to force all water out of the condenser?
Did you remove the condenser heads?
Warning: Water left in the piping and vessels can rupture these parts if subjected to freezing temperature.
Did you circulate antifreeze through the water circuits?
Take measures to prevent the shutoff valve in the water supply line from being accidentally turned on.
Did you remove the pump drain plug in the water pump?
Initial 500 Hours Oil Condition Check
Key to Action
1) Re-sample after 500 hours of unit operation.
a) If content increases less than 10%, change oil and oil filter and re-sample at normal interval (usually annual).
b) If content increases between 11% and 24%, change oil and oil filter and re-sample after an additional 500 hours of operation.
c) If content increases more than 25%, inspect compressor for cause.
2) Re-sample after 500 hours of unit operation.
a) If content increases less than 10%, change filter-drier and re-sample at normal interval (usually annual).
b) If content increases between 11% and 24%, change filter-drier and re-sample after an additional 500 hours of operation.
c) If content increases more than 25%, monitor for a water leak.
Electrical System Maintenance
General Requirement
Are contacts clean?
Are connections tight?
Specific Items
Compressor current draw
Compare the compressor current draw to the nameplate RLA value. Normally, the actual current will be lower, since the nameplate rating represents full load operation.
Pump motor amperage
Fan motor amperage
Compare all pump and fan motor amperages with nameplate ratings.
1 Weekly Refrigerant Leak Test
Warning: Do not use oxygen or a mixture of R-22 and air to build up pressure as an explosion can occur causing serious personal injury.
Enter the initial pressure of the system in psig
Enter the pressure after adding refrigerant in psig
Enter the pressure after adding dry nitrogen in psig
Leak test with an electronic leak detector passed?
Water flow through the vessels maintained during the procedure?
Any leaks found in welded or brazed joints?
Was it necessary to replace a gasket?
If any leaks are found in welded or brazed joints, or it is necessary to replace a gasket, relieve the test pressure in the system before proceeding.
Oil Filter Replacement
Warning: This procedure requires trained personnel with PPE!
Daikin chillers are at positive pressure at all times and do not leak contaminated moist air into the refrigerant circuit, thereby eliminating the need for annual oil changes.
An annual laboratory oil check is recommended to check overall compressor condition.
Isolate the filter cavities. Close the oil discharge line service valve at the oil pump (at the filter on CE126).
Remove the filter cover; some foaming can occur but the check valve should limit leakage from other compressor cavities.
Remove the filter, replace with new element, and replace filter cover using a new gasket.
Reopen the valve in the pump discharge line and purge air from the oil filter cavity.
When machine is operated again, the oil level must be checked to determine if oil needs to be added to maintain the proper operating level.
Sign off on the oil filter replacement
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX