Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Indoor Unit Cooling Only Air Conditioner FTKD25GVMV
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
PCB Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Shield plate removed
Indoor heat exchanger thermistor released
Terminal board removed
Signal receiver unit removed
Signal receiver PCB removed
INTELLIGENT EYE sensor PCB removed
Display PCB removed
Control PCB removed
Front Grille Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Remove the screw covers and screws. (right and left)
Open the horizontal blades before removing the screw covers and screws.
When reassembling the indoor unit, drive the screws with the horizontal blades opened or removed.
Unfasten the 3 hooks on the top of the front grille.
The convex marks (...) on the front panel indicate the position of the hooks.
Pull the upper part of the front grille out and lift the lower part up, and then remove the front grille.
When reassembling, make sure that the 3 hooks are fastened as they were.
When reassembling the front grille, be sure not to get it stuck on the spacer of the drain pan.
Front Panel Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Open the front panel over the position where it stops.
Slide the left rotary shaft to the right and release it.
Remove the right rotary shaft in the same way.
When reassembling the front panel, fit the right and left rotary shafts one by one into the grooves and fully push them into position.
Sign off on the front panel removal
Air Filter Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Remove the air filters.
The air filter is not marked for difference between the right and left sides.
Insert the air filter with the “FRONT” mark faced up.
The air filter can be set easily by inserting it along the guides.
Be sure to insert the hooks (at 2 lower positions) when mounting the air filter.
1) Open the front panel.
2) Pull out the air filter downward and remove it.
2. Remove the Titanium apatite photocatalytic airpurifying filters.
Drain Pan Unit / Swing Motor Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Remove the drain pan unit.
Inserting a wooden base beneath the unit facilitates the removing work.
Lift up the indoor unit slightly and pull out the drain hose.
Place a plastic sheet under the drain pan to prevent from wetting the floor with remaining drain.
1) Remove the screw at the right side of the drain pan unit.
2) Press the right side of the drain pan unit and twist the left side.
3) Remove the drain pan unit from the indoor unit.
When reassembling, make sure that the hook at the left side is fitted in the groove.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













