The Cummins Natural Gas Generator C100N6 is a reliable and efficient power solution designed for various industrial applications. With its robust engineering and advanced technology, this generator ensures optimal performance and longevity, making it an ideal choice for businesses seeking dependable energy sources.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Cummins Natural Gas Generators C100N6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
12 Monthly or 250 Hourly Natural Gas Generators Maintenance
Air cleaner replaced
Coolant lines and radiator hoses checked for leaks, wear and cracks
Radiator core cleaned
Water pump checked for leaks
Coolant heater checked for power and leaks
CCV heater checked for leaks
Alternator heater checked for general condition and wiring connections
Battery heater checked for general condition and wiring connections
Engine oil heater checked for general condition and wiring connections
1 Daily or 24 Hourly Natural Gas Generators Maintenance
Check air cleaner restriction indicator
Check air intake system for leaks
Check coolant level of radiator
Check cooling fan blades
Checking drive belt condition and tension
Check radiator airflow
Check fuel lines and hoses
Check engine oil level
Make sure the generator set is shut down and disabled
1 Weekly or 50 Hourly Natural Gas Generators Maintenance
Check operation of Emergency Stop Button
Check all systems before resetting the fault.
Replace engine oil and filters.
Before changing the oil, the generator set should be operated until the water temperature is approximately 60 C (140 °F).
Make sure the generator set is shut down and disabled.
Press the generator set's 'O' (Off) button to stop the generator set. Allow the generator set to thoroughly cool to the touch.
If applicable, turn off and disconnect the battery charger from the AC source before disconnecting the battery cables.
Disconnect the negative (-) cable from the battery and secure it from contacting the battery terminals to prevent accidental starting.
Drain the oil. Place the end of the drain hose into an appropriate container.
2 Yearly or 500 Hourly Natural Gas Generators Maintenance
Replace spark plugs and spark plug wires.
Check valve lash and adjust if required. See the Valve Clearance Adjustment procedure (service manual only).
Check fan drive idler arm and fan belt tensioner for general condition, as well as for excessive play in both.
Replace cooling system coolant. Check coolant sensor for damage and debris.
Sign off on the maintenance procedure
Air Intake System Maintenance
Warning: Holes, loose-end seals, dented sealing surfaces, corrosion of pipes, and other forms of damage render the air cleaner inoperative and require immediate element replacement or engine damage can occur.
Notice: Cummins Inc. does not recommend cleaning paper-type air cleaner elements.
Check for any debris accumulated around the air cleaner connection to the engine.
Upload a photo of the dirty air cleaner before removal.
Was the dirty air cleaner removed successfully?
Dispose of the dirty element in accordance with local environmental agency requirements.
Upload a photo of the replacement air cleaner before installation.
Was the replacement air cleaner installed successfully?
Enter the torque applied to the strap clamp (in Nm).
Access the parts list for your equipment in MaintainX.
Barring Tool
3824591
Capscrew
3823921
EControls GCP E-Com USB Interface Cable
A047A982
Electronic Cleaner
3824510
Guide Pins
3164977
Barring Tool
3824591
Capscrew
3823921
EControls GCP E-Com USB Interface Cable
A047A982
Electronic Cleaner
3824510
Guide Pins
3164977
Barring Tool
3824591
Capscrew
3823921
EControls GCP E-Com USB Interface Cable
A047A982
Electronic Cleaner
3824510
Guide Pins
3164977
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX