MaintainX Asset Hub logo
EnterprisePricing
Kaeser

Kaeser Screw Compressor BSD 50

Need answers fast?
Explore the manual using AI.

Kaeser Screw Compressor BSD 50
Kaeser Screw Compressor BSD 50

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Kaeser Screw Compressor BSD 50

Kaeser Screw Compressor BSD 50

Create an account to install this asset package.

Maintenance Plans for Kaeser Screw Compressor Model BSD 50

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly Compressor Maintenance

Check mark

Cooler Maintenance

Check mark

Regular cleaning of the cooler done?

Check mark

Do not use sharp objects to clean the cooler. It could be damaged.

Check mark

Avoid creating clouds of dust.

Check mark

Dry brush the oil and air coolers and use a vacuum cleaner to suck up the dirt.

Check mark

Check the cooling air filter mat

Check mark

The filter mat helps to keep the cooler clean. If the filter mat is clogged, adequate cooling of the components is no longer ensured.

Check mark

Check the condition of the filter.

Check mark

Sign off on the compressor maintenance

Run this procedureArrow right

1 Weekly Compressor Maintenance

Check mark

WARNING: Danger of burning from hot surfaces! Wear long-sleeved clothing and protective gloves.

Check mark

Has the machine been running at least 5 minutes under LOAD?

Check mark

Check the cooling oil level

Check mark

Is the indicator showing minimum level?

Check mark

If the indicator shows minimum level, top up the cooling oil.

Check mark

Check the Filter Mat

Check mark

If the filter mats are clogged, adequate cooling of the components is no longer ensured. In such a case, clean or replace the filter mats.

Check mark

Sign off on the weekly compressor maintenance

Run this procedureArrow right

1 Yearly Compressor Maintenance

Check mark

Safety Precautions

Check mark

Safety relief valve check

Check mark

Notes on safety relief valve check

Check mark

Overheating safety shutdown function check

Check mark

Notes on overheating safety shutdown function check

Check mark

Cooler leak check

Check mark

Notes on cooler leak check

Check mark

Water-cooling maintenance

Check mark

Notes on water-cooling maintenance

Run this procedureArrow right

1 Yearly SIGMA CONTROL Display Maintenance

Check mark

Precondition: The power supply disconnecting device is switched off. The disconnecting device is locked in the off position. A check has been made that no voltage is present. The machine has cooled down.

Check mark

Unscrew the nuts 4 and lift out the cover 3 together with the air filter element 2.

Check mark

Unscrew the nut 1 and remove the filter element.

Check mark

Renew the filter element.

Check mark

Clean all parts and sealing surfaces.

Check mark

Insert the air filter cartridge in the cover and secure with the nut 1.

Check mark

Insert the cover in the machine and secure with nuts 4.

Check mark

Close all access doors and replace all enclosure panels.

Check mark

Switch on the power supply and reset the maintenance interval counter.

Run this procedureArrow right

3000 Hourly Compressor Maintenance

Check mark

Change the cooling air filter mat

Check mark

Is the machine switched off?

Check mark

Removal

Check mark

Open the fixing (3) by turning 90 Degree counter clockwise with a screwdriver.

Check mark

Remove the frame.

Check mark

Renew the mat.

Check mark

Refitting

Check mark

Replace the frame and close the fixings.

Check mark

Use a screwdriver to turn the fixings 90 Degree clockwise until they latch.

Run this procedureArrow right

Parts for Kaeser Screw Compressor BSD 50

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Airend Installation Kit

4100

Airend Installation Kit

4100

Air Filter

1250

Air Filter

1250

Air Filter Element

1250

Airend Installation Kit

4100

Airend Installation Kit

4100

Air Filter

1250

Air Filter

1250

Air Filter Element

1250

Airend Installation Kit

4100

Airend Installation Kit

4100

Air Filter

1250

Air Filter

1250

Air Filter Element

1250

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Kaeser

Explore Other Assets