The Kaeser Rotary Screw Compressor SM 15 is a reliable and efficient industrial compressor designed for continuous operation. Known for its durability and low maintenance requirements, this model offers superior performance in various applications, making it an ideal choice for businesses seeking high-quality compressed air solutions.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Kaeser Rotary Screw Compressor SM 15
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly Compressor Maintenance
Cooler Maintenance:
- Regular cleaning of the cooler ensures reliable cooling of the machine and the compressed air. The frequency is mainly dependent on local operating conditions.
A filter mat helps to keep the cooler clean. Despite this fact, the cooler will clog over a period of time. Do not use sharp objects to clean the cooler. It could be damaged.
Avoid creating clouds of dust.
1. Carefully remove the filter mat from the retaining frame.
2. Dry brush the oil and air coolers and use a vacuum cleaner to suck up the dirt.
3. Carefully insert the filter mat in the retaining frame.
Check the Air Filter:; Precondition:; - The power supply disconnecting (isolating) device is switched off.
- The disconnect device is locked in the off position.
12000 Hourly Drive Belt Replacement
Precondition: The power supply isolating device is switched off. The device is locked off. The absence of any voltage has been verified. The machine has cooled down. WARNING: Touching the moving drive belt may result in severe bruising or even loss of limb or extremities.
Switch off and lock out the power supply isolating device and verify the absence of voltage.
Loosen the locking nut (2).
Turn adjusting nut (1) to loosen the tension on the belt until it can be removed from the pulley.
Install the new belt and use the adjusting nut (1) to adjust tension until the marker pin reaches the lower end of the elongated hole.
Tighten the locking nut (2).
Sign off on the belt replacement
1 Weekly Compressor Maintenance
Checking the coolant oil level:
- The sightglass allows a risk-free reading of the cooling oil level. The oil indicator should be fully filled with oil when the machine is at standstill.
- The ideal situation is with the oil level around the optimum mark when the machine is running.
Cooler: Check the Filter Mats:
- The filter mats help to keep the cooler clean. If the filter mats are clogged, adequate cooling of the components is no longer ensured.
Control Cabinet: Check the Filter Mat:
- A filter mat is placed behind every ventilation grill. Filter mats protect the control cabinet from ingress of dirt. If the filter mats are clogged, adequate cooling of the components is no longer ensured. In such a case, clean or replace the filter mats.;
1 Yearly Compressor Maintenance
1. Check the safety relief valve: In order to check the safety relief valve, the machine's working pressure is raised above the activating pressure of the valve.
Important Notes:
- Blow-off protection and air system pressure monitoring are switched off during the test.
- During normal operation, the blow-off protection switches off the machine before the safety relief valve responds.
- During inspection, the blow-off protection will switch off the machine only when the activating pressure of the safety relief valve has been exceeded by 14.7 psig.
Instructions:
- Follow the detailed procedure in the SIGMA CONTROL 2 operating manual.
- Never operate the machine without a correctly functioning safety relief valve.
- Replace a defective safety relief valve immediately.
1 Yearly SIGMA CONTROL 2 Maintenance
Checking the Belt Tension and Adjustment
Adjust the tension when the marker pin reaches the top end of the elongated hole.
Loosen the locking nut (2).
Use the adjusting nut (1) to adjust the spring tension until the marker pin reaches the lower end of the elongated hole.
Tighten the locking nut (2).
Visually Check for Damages
Turn the pulley by hand so that all of the belt can be inspected for damage.
In case of damage: Replace the drive belt immediately.
Change the air filter
Access the parts list for your equipment in MaintainX.
Airend Installation Kit
4100
Air Filter Element
1250
Bearing Set, Drive Motor
4451
Combination Valve
2060
Control Line Kit
7350
Airend Installation Kit
4100
Air Filter Element
1250
Bearing Set, Drive Motor
4451
Combination Valve
2060
Control Line Kit
7350
Airend Installation Kit
4100
Air Filter Element
1250
Bearing Set, Drive Motor
4451
Combination Valve
2060
Control Line Kit
7350
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX