MaintainX Logo
EnterprisePricing
Carrier

Carrier Packaged and Dedicated Outdoor Air Units 62X

Need answers fast?
Explore the manual using AI.

Carrier Packaged and Dedicated Outdoor Air Units 62X
Carrier Packaged and Dedicated Outdoor Air Units 62X

Carrier Packaged and Dedicated Outdoor Air Units 62X are designed for efficient climate control in commercial settings. These units provide reliable performance and energy efficiency, making them ideal for various applications. Regular maintenance ensures optimal operation and longevity of the system.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Carrier Packaged and Dedicated Outdoor Air Units 62X

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Carrier Packaged and Dedicated Outdoor Air Units 62X

Carrier Packaged and Dedicated Outdoor Air Units 62X

Create an account to install this asset package.

Maintenance Plans for Carrier Packaged and Dedicated Outdoor Air Units Model 62X

Integrate maintenance plans directly into your work orders in MaintainX.

Electric Heater Wiring and Wiring Connections

Check mark

All wiring connections checked and tightened as necessary

Check mark

Internal wiring checked and replaced as necessary with type THHN 221°F (105°C), 600V, 16-gauge wire or equivalent

Check mark

Heater control panel checked for dust/dirt and moisture and cleaned as necessary

Check mark

Heating elements checked for dust/dirt buildup and/or broken elements. Elements replaced and/or cleaned with low pressure air as necessary

Check mark

Element male/female chassis insulators checked for breaks and/or cracks. Replaced as necessary

Check mark

Element support frame insulators checked. Missing or broken insulators replaced as necessary

Check mark

Sign off on the electric heater wiring and wiring connections

Run this procedureArrow right

Energy Conservation Wheel

Check mark

BEARINGS

Check mark

Check if small ECWs require maintenance

Check mark

Check if larger ECWs are greased annually

Check mark

DRIVE MOTOR

Check mark

Check if drive motors require maintenance

Check mark

DRIVE BELTS

Check mark

Check if belts require adjustment or replacement

Check mark

SEALS

Check mark

Check if seals require adjustment or replacement

Run this procedureArrow right

Packaged and Dedicated Outdoor Air Units Maintenance

Check mark

Inspect blower wheel and clean as necessary

Check mark

Check for excessive vibration in blower wheel

Check mark

Fix scratches on cabinet exterior

Check mark

Inspect the caulk annually and re-apply as needed

Check mark

Verify that no flammable objects, liquids, or vapors are present near the unit

Check mark

Ensure free movement of condensing fans

Check mark

Check that all fan mounting hardware is tight

Check mark

Check motor bearings for wear

Check mark

Check for blockages in condensate drain pan and drain

Run this procedureArrow right

Refrigeration Circuit Components

Check mark

Check evaporator coil for dirt and bent fins.

Check mark

Clean evaporator coil with water from blower side towards filter side.

Check mark

Check condenser coil for dirt and bent fins.

Check mark

Clean condenser coil by brushing off with broom.

Check mark

Check compressors for any maintenance requirement.

Check mark

Note: Compressors are factory-supplied with a charge of oil and should not require additional maintenance.

Run this procedureArrow right

3 Monthly Motor Maintenance

Check mark

MOTORS

Check mark

Inspection

Check mark

Inspect motor every 3 months.

Check mark

Keep the motor clean and vent openings clear.

Check mark

Lubrication

Check mark

Choose the type of motor

Check mark

Lubricating Instructions

Check mark

Before greasing, be sure fittings are clean and free from dirt.

Check mark

Remove grease relief plug or plate and, using a low-pressure grease gun, pump in the required grease.

Run this procedureArrow right

Parts for Carrier Packaged and Dedicated Outdoor Air Units 62X

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Rotation Label

0527N-0620

R-410A Label

91060002

Hot Surtace Label

9-21577

Door Latch Label

91031108

MDC Board

0872P-0105

Rotation Label

0527N-0620

R-410A Label

91060002

Hot Surtace Label

9-21577

Door Latch Label

91031108

MDC Board

0872P-0105

Rotation Label

0527N-0620

R-410A Label

91060002

Hot Surtace Label

9-21577

Door Latch Label

91031108

MDC Board

0872P-0105

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Carrier

Explore Other Assets