Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Cambridge Air Solutions Space Heater S800

Cambridge Air Solutions Space Heater S800

Create an account to install this asset package.

Maintenance Plans for Cambridge Air Solutions Space Heater Model S800

Integrate maintenance plans directly into your work orders in MaintainX.

Valve Disassemble

Check mark

ASCO Gas Valves: Series 8214

Check mark

Disassemble the valve

Check mark

Remove the solenoid enclosure

Check mark

Remove the bonnet screws, valve bonnet, bonnet gasket, core/diaphragm subassembly and body gasket

Check mark

Lubrication

Check mark

Lubricate the bonnet gasket and body gasket with Dow Corning® 200 Fluid lubricant or equivalent

Check mark

Apply RemGrit TFL 50® Dry Lubricant to valve seat, valve body surface, and internal surface of valve bonnet

Check mark

Lubricate with RemGrit TFL 50® Dry Lubricant if not installing Rebuild Kit

Check mark

Reassembly

Run this procedureArrow right

Gas Valve Cleaning

Check mark

Pre-Cleaning Safety Measures

Check mark

Turn off the electrical power

Check mark

Close the upstream manual gas valve

Check mark

Depressurize the valve

Check mark

Extinguish all open flames

Check mark

Avoid any type of sparking or ignition

Check mark

Vent hazardous or combustible fumes to a safe area

Check mark

Valve Cleaning

Check mark

Check for indicators of cleaning requirement

Run this procedureArrow right

Motor Bearing Lubrication

Check mark

Safety Precautions

Check mark

Turn off the disconnect switch

Check mark

Lubrication Process

Check mark

Verify grease compatibility

Check mark

Apply grease to motor bearings

Check mark

Post-Lubrication Check

Check mark

Is the motor operating smoothly after lubrication?

Run this procedureArrow right

Blower Bearing Lubrication

Check mark

!WARNING: Turn the disconnect switch off when performing service or maintenance functions.

Check mark

Blower Bearing Lubrication

Check mark

Verify motor size and lubrication requirement

Check mark

Select the grease to be used

Check mark

Ensure grease is bearing quality and compatible with lithium bases thickener

Check mark

Is the lubrication interval between 3 to 6 months?

Check mark

Lubricate the blower bearing if required

Run this procedureArrow right

Belt Tension Check

Check mark

Belt Tension Verification

Check mark

Use a Browning Belt Tension Checker to measure belt tension

Check mark

Use a straight edge to verify belt alignment

Check mark

Record the measured belt tension

Check mark

Belt Condition Assessment

Check mark

Is the belt tension within the recommended range?

Check mark

Are there any indications of loose belts (e.g., barking or squealing)?

Check mark

Adjustment and Finalization

Check mark

Perform periodic belt adjustments if necessary

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Cambridge Air Solutions

Explore Other Assets