MaintainX Asset Hub logo
EnterprisePricing
Burton Medical

Burton Medical Medical Light ALEDSC

Need answers fast?
Explore the manual using AI.

Burton Medical Medical Light ALEDSC
Burton Medical Medical Light ALEDSC

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Burton Medical Medical Light ALEDSC

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Burton Medical Medical Light ALEDSC

Burton Medical Medical Light ALEDSC

Create an account to install this asset package.

Maintenance Plans for Burton Medical Medical Light Model ALEDSC

Integrate maintenance plans directly into your work orders in MaintainX.

Module Replacement

Check mark

Preparation

Check mark

Ensure all necessary tools are available

Check mark

Module Removal

Check mark

Remove the three screws and the top lid

Check mark

Disconnect the wires for the LED module from the terminal block next to the cooling fan in the center

Check mark

Loosen the two pivot screws

Check mark

Module Replacement

Check mark

Remove the old LED and replace with the new in reverse order

Check mark

Post Replacement Check

Run this procedureArrow right

Light Normal Cleaning

Check mark

Safety Precautions

Check mark

Power off the equipment and secure it from being switched on again.

Check mark

Ensure no cleaning fluid runs into the equipment.

Check mark

Cleaning Instructions

Check mark

Select the cleaning agent used

Check mark

Use a soft cloth dampened with the selected cleaning agent for basic cleaning of all surfaces on the AIM luminaires.

Check mark

Was a soft cloth soaked in isopropyl alcohol used for stubborn stains?

Run this procedureArrow right

1300 Hourly / 12 Monthly Light Maintenance

Check mark

WARNING: Maintenance Schedule Suggestion

Check mark

WARNING: Equipment Malfunction

Check mark

Remove top housing and clean accessible parts

Check mark

Check and adjust friction between light head and yoke shaft if needed

Run this procedureArrow right

Light Extensive Cleaning

Check mark

Preparation

Check mark

Ensure the light is turned off and unplugged

Check mark

Removing Top Housing

Check mark

Remove pods to access screws (if applicable)

Check mark

Remove screws to detach top housing

Check mark

Cleaning Process

Check mark

Use a soft cloth to wipe corners and surfaces

Check mark

Ensure no components inside the light head are bent or damaged

Check mark

Reassembly

Run this procedureArrow right

Light Head Rotating Friction Adjustment

Check mark

Preparation

Check mark

Remove the pods to access the screws holding the housing together

Check mark

Remove the screws

Check mark

Adjustment

Check mark

Lift the top housing off

Check mark

Use a wrench to tighten the nuts on each shaft

Check mark

Rotate the light head to verify correct friction

Check mark

Reassembly

Check mark

Re-assemble the housing

Run this procedureArrow right

Parts for Burton Medical Medical Light ALEDSC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

LED Module

6000161

AIM LED 100V-240V; Fuse T, 2AL 250V 5x20mm

7023

AIM LED 100V, 120V Version; Fuse T, 3A, 250V, 5x20mm

4000025

Window (AIM LED)

5000181

Reflector

1019000

LED Module

6000161

AIM LED 100V-240V; Fuse T, 2AL 250V 5x20mm

7023

AIM LED 100V, 120V Version; Fuse T, 3A, 250V, 5x20mm

4000025

Window (AIM LED)

5000181

Reflector

1019000

LED Module

6000161

AIM LED 100V-240V; Fuse T, 2AL 250V 5x20mm

7023

AIM LED 100V, 120V Version; Fuse T, 3A, 250V, 5x20mm

4000025

Window (AIM LED)

5000181

Reflector

1019000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Burton Medical

Explore Other Assets