Bradford White Water Heater RG2PV75H6X19
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Anode Inspection
Anode Inspection & Replacement
Take necessary precautions to prevent personal injury
Position on/off switch of gas control valve to the 'OFF' position and unplug water heater from wall outlet
Turn off cold water supply to water heater
Connect hose to drain valve of water heater and route to an open drain
Open a nearby hot water faucet to vent water heater for draining
Open drain valve of water heater and allow water heater to drain to a point below the outlet connection nipple
Disconnect outlet nipple from plumbing system
Remove outlet nipple/anode from the water heater using an appropriate tool such as a pipe wrench
115 VAC Circuit Testing
115 VAC Circuit Trace
Verify 115 VAC and proper polarity at wall outlet
With unit plugged in and control power switch in the “ON” position verify LED status
6 Monthly Burner Inspection
Burner Inspection
Check for causes of unstable pilot flame
Inspect pilot flame stability
Inspect main burner flame color and stability
Check for debris accumulation on main burner
Is the main burner free from debris?
Pressure Switch Testing
Pressure Switch Testing
Position power switch on gas control to the “OFF” position.
Remove the three screws from control access cover on blower assembly and remove cover.
Remove pressure switch from blower housing
Note any warnings or precautions taken during the procedure.
To resume operation, follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.
Flame Arrestor Cleaning
ScreenLok® Flame Arrestor Cleaning
Is the model equipped with the ScreenLok® Flame Arrestor?
Position Gas Control power switch to the “OFF” position.
Remove outer door.
Remove outer jacket door and inner door per service procedure XIII on page 39.
Disconnect main burner feedline (3/4” wrench), pilot tube (7/16” wrench) and igniter/flame sensor wire from gas control and remove burner assembly from combustion chamber.
Clean ScreenLok® Flame Arrestor using stiff brush, compressed air and/or shop vacuum to remove any scale or other debris accumulation.
Using a soft brush, clear jacket openings from any dirt, dust, restrictions or other obstructions.
Remove any debris from burner assembly per PROCEDURE I and reinstall burner assembly into combustion chamber.
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX