Bradford White Water Heater RG2PV50H6X19
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Cleaning
Burner Cleaning
Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
Turn off gas supply to water heater.
Remove outer jacket door and inner door per service procedure XIII on page 39.
Disconnect pilot tube (7/16” wrench) and feedline (3/4” wrench) from gas control.
Disconnect igniter/flame sensor wire from gas control.
Remove burner assembly from combustion chamber.
Thoroughly inspect burner surface area and burner port area and remove any loose debris.
Unscrew burner from main burner orifice.
Flame Arrestor Cleaning
ScreenLok® Flame Arrestor Cleaning
Is the model equipped with the ScreenLok® Flame Arrestor?
Position Gas Control power switch to the “OFF” position.
Remove outer door.
Remove outer jacket door and inner door per service procedure XIII on page 39.
Disconnect main burner feedline (3/4” wrench), pilot tube (7/16” wrench) and igniter/flame sensor wire from gas control and remove burner assembly from combustion chamber.
Clean ScreenLok® Flame Arrestor using stiff brush, compressed air and/or shop vacuum to remove any scale or other debris accumulation.
Clear jacket openings from any dirt, dust, restrictions or other obstructions using a soft brush.
Remove any debris from burner assembly per PROCEDURE I and reinstall burner assembly into combustion chamber.
Manifold Pressure Testing
Line Pressure
Verify line pressure limits
Is the line pressure checked with the main burner on and off?
Manifold Pressure Testing
Set the Gas Control to the “OFF” position.
Remove pressure tap plug and install 1/8” NPT pipe, coupling & pressure tap.
Connect manometer to pressure tap.
Light the main burner and observe manometer reading.
Enter the manometer reading for Natural Gas
115 VAC Circuit Testing
115 VAC Circuit Trace
Verify 115 VAC and proper polarity at wall outlet
With unit plugged in and control power switch in the “ON” position verify LED status
Safety Circuit Voltage Testing
Safety Circuit Voltage Trace
Ensure safety precautions are in place
Remove three screws from control access cover on blower using a Phillips screwdriver
Remove control access cover from blower
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX