Bradford White Water Heater RG2PV40T6X19
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Cleaning
Burner Cleaning
Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
Turn off gas supply to water heater.
Remove outer jacket door and inner door per service procedure XIII on page 39.
Disconnect pilot tube (7/16” wrench) and feedline (3/4” wrench) from gas control.
Disconnect igniter/flame sensor wire from gas control.
Remove burner assembly from combustion chamber.
Thoroughly inspect burner surface area and burner port area and remove any loose debris.
Unscrew burner from main burner orifice.
Blower Maintenance
Blower Removal
Position gas control power switch to 'OFF' position and adjust control to call for heat.
Unplug blower power cord from wall outlet.
Disconnect vent system from exhaust adapter on top of blower.
Remove exhaust adapter from blower and retain for use on new blower.
Unplug cord sets from blower.
Remove the three blower mounting screws.
Remove blower with gasket from water heater.
Blower Installation
Pilot Inspection
Pilot Inspection, Testing and Replacement
Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
Turn off gas supply to water heater.
Remove outer jacket door and inner door per service procedure XIII on page 39.
Disconnect pilot tubing nut (7/16” wrench) and feedline nut (3/4” wrench) from gas control.
Disconnect igniter/flame sense wire from gas control.
Remove burner assembly from combustion chamber.
Remove pilot assembly from feedline (1/4” nut driver).
Visually inspect igniter/flame sense wire for damage. Replace pilot if damage is found.
Gas Control Maintenance
Gas Control Removal From Water Heater
Position the gas control power switch to the “OFF” position and unplug heater from wall outlet.
Drain the heater to a point below the gas control level.
Turn off the gas supply to the water heater and disconnect gas piping from the gas control.
Disconnect wire harnesses from the gas control.
Remove the outer jacket burner access door.
Right Side Inner Door Removal
Remove (2) hex drive screws from RIGHT side inner door.
Remove (2) hex drive screws from FLANGE SECTION of inner door.
115 VAC Circuit Testing
115 VAC Circuit Trace
Verify 115 VAC and proper polarity at wall outlet
With unit plugged in and control power switch in the “ON” position verify LED status
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX