MaintainX, an Autodesk company
EnterprisePricing
Bradford White

Bradford White Water Heater RG2PV40T6N19

Need answers fast?
Explore the manual using AI.

Bradford White Water Heater RG2PV40T6N19
Bradford White Water Heater RG2PV40T6N19

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Bradford White Water Heater RG2PV40T6N19

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Bradford White Water Heater RG2PV40T6N19

Bradford White Water Heater RG2PV40T6N19

Create an account to install this asset package.

Maintenance Plans for Bradford White Water Heater Model RG2PV40T6N19

Integrate maintenance plans directly into your work orders in MaintainX.

Blower Maintenance

Check mark

Blower Removal

Check mark

Position gas control power switch to 'OFF' position and adjust control to call for heat.

Check mark

Unplug blower power cord from wall outlet.

Check mark

Disconnect vent system from exhaust adapter on top of blower.

Check mark

Remove exhaust adapter from blower using a blade screwdriver and retain for use on new blower.

Check mark

Unplug cord sets from blower.

Check mark

Remove the three blower mounting screws using a 1/4” nut driver.

Check mark

Remove blower with gasket from water heater.

Check mark

Blower Installation

Run this procedureArrow right

Pressure Switch Testing

Check mark

Pressure Switch Testing

Check mark

Position power switch on gas control to the “OFF” position

Check mark

Remove the three screws from control access cover on blower assembly and remove cover

Check mark

Remove pressure switch from blower housing

Check mark

Resume operation following the lighting instructions

Check mark

Safety Precautions

Check mark

Use caution to avoid personal injury due to 115 volt potential exposure

Run this procedureArrow right

Safety Circuit Voltage Testing

Check mark

Safety Circuit Voltage Trace

Check mark

Ensure safety precautions are in place

Check mark

Remove three screws from control access cover on blower using a Phillips screwdriver

Check mark

Remove control access cover from blower

Run this procedureArrow right

Temperature Sensor Testing

Check mark

Temperature Sensor Testing

Check mark

Use special pin type electronic probes or small diameter wire pins inserted into connector

Check mark

Insert one meter probe into center wire position of temperature sensor connector

Check mark

Insert the second probe into either of the outside wire positions

Check mark

Alternate the probe on the outside position to the opposite outside wire position

Check mark

Has the control gone into lockout due to excessive tank temperature?

Check mark

Reset control by sliding gas control knob to 'OFF' position and wait a minimum of 5 minutes

Check mark

Follow lighting instructions and return gas control knob to desired setpoint

Check mark

Observe Green LED indication. Does error code 4 continue?

Run this procedureArrow right

Inner Door Maintenance

Check mark

SECTION: Inner Door Removal Procedure

Check mark

1. Position gas control power switch to the “OFF” position.

Check mark

2. Remove outer jacket burner access door.

Check mark

3. Inner Door removal.

Check mark

a. Remove (2) ¼” hex drive screws from right side inner door.

Check mark

b. Remove (2) ¼” drive screws from flange section of inner door.

Check mark

c. Remove (2) ¼” drive screws from left side inner door.

Check mark

d. Remove inner door and inspect per step 4.

Check mark

4. Fully inspect inner door gaskets for the following: Tears, Missing Material, Cracks, Dirt or debris, Other imperfections that will inhibit proper seal, Gasket adhesion to inner door, Material left on combustion chamber (around opening).

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Bradford White

Explore Other Assets