Bradford White Water Heater RG2PV40T6N19
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Blower Maintenance
Blower Removal
Position gas control power switch to 'OFF' position and adjust control to call for heat.
Unplug blower power cord from wall outlet.
Disconnect vent system from exhaust adapter on top of blower.
Remove exhaust adapter from blower using a blade screwdriver and retain for use on new blower.
Unplug cord sets from blower.
Remove the three blower mounting screws using a 1/4” nut driver.
Remove blower with gasket from water heater.
Blower Installation
Pressure Switch Testing
Pressure Switch Testing
Position power switch on gas control to the “OFF” position
Remove the three screws from control access cover on blower assembly and remove cover
Remove pressure switch from blower housing
Resume operation following the lighting instructions
Safety Precautions
Use caution to avoid personal injury due to 115 volt potential exposure
Safety Circuit Voltage Testing
Safety Circuit Voltage Trace
Ensure safety precautions are in place
Remove three screws from control access cover on blower using a Phillips screwdriver
Remove control access cover from blower
Temperature Sensor Testing
Temperature Sensor Testing
Use special pin type electronic probes or small diameter wire pins inserted into connector
Insert one meter probe into center wire position of temperature sensor connector
Insert the second probe into either of the outside wire positions
Alternate the probe on the outside position to the opposite outside wire position
Has the control gone into lockout due to excessive tank temperature?
Reset control by sliding gas control knob to 'OFF' position and wait a minimum of 5 minutes
Follow lighting instructions and return gas control knob to desired setpoint
Observe Green LED indication. Does error code 4 continue?
Inner Door Maintenance
SECTION: Inner Door Removal Procedure
1. Position gas control power switch to the “OFF” position.
2. Remove outer jacket burner access door.
3. Inner Door removal.
a. Remove (2) ¼” hex drive screws from right side inner door.
b. Remove (2) ¼” drive screws from flange section of inner door.
c. Remove (2) ¼” drive screws from left side inner door.
d. Remove inner door and inspect per step 4.
4. Fully inspect inner door gaskets for the following: Tears, Missing Material, Cracks, Dirt or debris, Other imperfections that will inhibit proper seal, Gasket adhesion to inner door, Material left on combustion chamber (around opening).
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX