Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Compressor GA 22 VSD
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Compressor Check
Oil Level Check
Check oil level
Is oil top-up needed?
Top up the oil if needed
Check readings on display
Condensate Discharge Check
Wait for condensate discharge during operation
Use test button on electronic water drain to check drain function
Wait for condensate discharge by dryer drain during operation
Cooler Cleaning
General Procedure for Coolers
Stop the compressor, close the air outlet valve and switch off the voltage.
Cover all parts underneath the cooler.
Remove the service plate at the fan compartment.
Remove dirt from the coolers with a fibre brush, brushing in the direction of the cooling fins.
Remove dirt from the fan with a fibre brush.
Clean with an air jet in the direction of the normal flow.
Is it necessary to wash the coolers with a cleaning agent?
Remove the material that was used as cover after maintenance on the fan and on the coolers.
1 Monthly Compressor Maintenance
RH Sensor Maintenance
Check the relative humidity sensor
Clean the relative humidity sensor
Condenser Cleaning
Stop the compressor
Close the air outlet valve
Switch off the voltage
Remove dirt on the condenser inlet with a vacuum cleaner
Clean with an air jet in the reverse direction to normal flow
4000 Hourly / 12 Monthly UD+ Filters Replacement
Pre-replacement checks
Record the current operating hours of the filter
Record the current pressure drop in mbar
Has it been 12 months since the last filter replacement?
Filter replacement criteria
Determine if filter replacement is needed based on the following criteria
Post-replacement actions
Replace the filter elements of the oil mist filters (UD+)
Verify the new filter is operating within the normal pressure range (200-250 mbar)
8000 Hourly / 2 Yearly Compressor Maintenance
Pre-Maintenance Safety Checks
Stop the compressor and switch off the voltage
Apply all relevant safety precautions
Use correct personal protection equipment (gloves and safety goggles)
Lock out, tag out
Air Filter Replacement
Remove the cover of the air filter by opening the clip system
Remove the filter element
Fit the new element and the cover
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX