MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Controller SRG-620

Need answers fast?
Explore the manual using AI.

Advantage Temperature Controller SRG-620
Advantage Temperature Controller SRG-620

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Controller SRG-620

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Controller SRG-620

Advantage Temperature Controller SRG-620

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Controller Model SRG-620

Integrate maintenance plans directly into your work orders in MaintainX.

Heater Replacement

Check mark

Preparation

Check mark

Disengage operations and ensure all system pressure is relieved and the unit’s pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Access and Drainage

Check mark

Remove the lift-off access panel and set aside.

Check mark

Drain machine by removing the pump casing drain plug.

Check mark

Heater Disconnection

Check mark

Remove heater’s junction box cover to locate wiring connections.

Check mark

Note the wiring connections for correct reinstallation.

Run this procedureArrow right

Sensor Probe Maintenance

Check mark

Temperature Probe Overview

Check mark

Describe the function of the temperature probe

Check mark

Verify automatic gain calibration within the controller electronics

Check mark

Locate the zero adjustment potentiometer on the CPU

Check mark

Sensor Probe Error Indication

Check mark

Is the sensor probe error indicated by three dashed lines on the temperature display?

Check mark

Reconnection Procedure

Check mark

Unplug the service connection

Check mark

Shake out any water from the connection

Run this procedureArrow right

Heater Contactor and Pump Motor Starter Inspection

Check mark

Heater Contactor Inspection

Check mark

Inspect the heater contactor for signs of wear or pitting

Check mark

Is the heater contactor cycling frequently?

Check mark

Replace the heater contactor if wear or pitting is observed

Check mark

Pump Motor Starter Inspection

Check mark

Inspect the pump motor starter for signs of wear or pitting

Check mark

Replace the pump motor starter if wear or pitting is observed

Check mark

Safety and Final Checks

Check mark

Ensure all components are not overheating

Run this procedureArrow right

Voltage Change

Check mark

Consult with Advantage Service Department

Check mark

Select conversion type

Check mark

Prepare for field voltage changeover

Check mark

Check items for replacement or rewiring

Check mark

Perform field voltage changeover

Check mark

Disengage operations and verify system pressure is relieved

Check mark

Disengage main power supply

Check mark

Gain access to the electrical panel

Check mark

Rewire the heater to the new voltage

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Preparation

Check mark

Shut down unit operations according to section 3.4 in the manual

Check mark

Ensure proper lock-out procedures are followed

Check mark

Is the system pressure eliminated and the unit’s pressure gauges reading '0' pressure?

Check mark

Pressure Switch Replacement

Check mark

Drain unit by removing the pump casing drain plug

Check mark

Remove the capillary connection from the cooling cylinder to the pressure switch

Check mark

Remove the brass elbow mounted on the pressure switch

Check mark

Remove the electrical connections to the pressure switch

Run this procedureArrow right

Parts for Advantage Temperature Controller SRG-620

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets