MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Control Unit SK-1080

Need answers fast?
Explore the manual using AI.

Advantage Temperature Control Unit SK-1080
Advantage Temperature Control Unit SK-1080

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Control Unit SK-1080

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Control Unit SK-1080

Advantage Temperature Control Unit SK-1080

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Control Unit Model SK-1080

Integrate maintenance plans directly into your work orders in MaintainX.

Instrument Controller Maintenance

Check mark

Preparation

Check mark

Disengage process operations according to the procedure outlined in section 3.4

Check mark

Ensure all system pressure is relieved and the unit's pressure gauges read '0'

Check mark

Disengage main power supply

Check mark

Verify the Power light on the display is 'off'

Check mark

Panel and Instrument Removal

Check mark

Remove the thermoformed front panel and set aside

Check mark

Open the hinged electrical cabinet panel cover

Check mark

Remove the following connections

Run this procedureArrow right

Pump Seal Replacement

Check mark

Preparation

Check mark

Disengage process operations and relieve all system pressure

Check mark

Disengage main power supply

Check mark

Verify the Power light on the display is 'off'

Check mark

Access Panel Removal

Check mark

Remove the lift-off access panel and set aside

Check mark

Remove the thermoformed panel attached by 4 small screws

Check mark

Drain and Disconnect

Check mark

Drain machine by removing the pump casing drain plug

Run this procedureArrow right

Cooling Valve Maintenance

Check mark

Initial Safety and Preparation

Check mark

Disengage process operations and verify all system pressure is relieved and the unit's pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Remove the lift-off access panel and set aside.

Check mark

Disconnect the valve wiring harness.

Check mark

Remove the AVT valve's drip cover.

Check mark

Motor/Gearbox Assembly Service

Check mark

Remove the 2 mounting screws securing the motor/gearbox assembly to the valve bracket.

Check mark

Remove the 2 screws securing the micro switch.

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Preparation and Safety

Check mark

Shut down unit operations according to section 3.4 in the manual.

Check mark

Ensure proper lock-out procedures are followed.

Check mark

Ensure system pressure is eliminated and the unit's pressure gauges read '0' pressure.

Check mark

Pressure Switch Removal

Check mark

Drain unit by removing the pump casing drain plug.

Check mark

Remove the capillary connection from the cooling cylinder to the pressure switch.

Check mark

Remove the brass elbow mounted on the pressure switch.

Check mark

Remove the electrical connections to the pressure switch.

Run this procedureArrow right

Flow Meter Maintenance

Check mark

Preparation

Check mark

Reduce process water temperature to below 85°F.

Check mark

Disengage process operations.

Check mark

Verify all system pressure is relieved and the pressure gauges read "0".

Check mark

Power Disengagement

Check mark

Disengage main power supply.

Check mark

Verify the Power light on the display is "off".

Check mark

Access Cooling Cylinder

Check mark

Remove the lift-off access panel to access the cooling cylinder.

Run this procedureArrow right

Parts for Advantage Temperature Control Unit SK-1080

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Motor/Pump Assembly 3HP AS5 2/4/3/60

6207040

Impeller B2-5264 5.25" AS5

4310605

Motor AE5/AS5/A5W 3HP #4551R

4757866

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Motor/Pump Assembly 3HP AS5 2/4/3/60

6207040

Impeller B2-5264 5.25" AS5

4310605

Motor AE5/AS5/A5W 3HP #4551R

4757866

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Motor/Pump Assembly 3HP AS5 2/4/3/60

6207040

Impeller B2-5264 5.25" AS5

4310605

Motor AE5/AS5/A5W 3HP #4551R

4757866

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets