Advanced Distributor Products Unit Heater SEP−175-S
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Combustion Air Inducer Check
Preparation
Disconnect power supply
Inspection and Cleaning
Inspect the combustion air inducer for any visible damage or wear
Clean the inducer wheel using a small brush
Post-Inspection
Is the combustion air inducer free of debris and functioning properly?
Flue And Chimney Check
Vent and Vent Connector Inspection
Check all vent and vent connector joints for tightness
Are all connections sealed?
Ensure there are no blockages in the vents
Post Inspection
Clean the inspection area
Inspector's signature
2 Yearly Motor Bearing Lubrication
Combustion Air Inducer Motor Bearings
Verify that combustion air inducer motor bearings are pre-lubricated and sealed
Fan Motor Bearings
Check for manufacturer's lubrication instructions on each fan motor
Re-lubricate fan motor bearings if no manufacturer's instructions are provided
Apply a few drops of SAE No 10 non-detergent oil to motors with oiling ports
Gas Pressure Adjustment
Gas Line Pressure Check
Check gas line pressure with unit firing at maximum rate
Is the gas line pressure within the specified range?
Regulator Pressure Adjustment
Check regulator pressure
Refer to figures 8, 9, and 10 for gas pressure adjustment screw location
Was the regulator pressure adjusted to the specified value?
Gas Type Conversion
Ensure a natural gas to LP/propane gas changeover kit is available
Burner Maintenance
Burner Flame Examination
Examine burner flames for proper appearance during the heating season
Pre-Heating Season Inspection
Examine burners for any deposits or blockage
Burner Cleaning Procedure
Turn off both electrical and gas supplies to unit
Disconnect gas supply piping, high tension and sensor leads
Remove gas manifold
Remove burner tray
Access the parts list for your equipment in MaintainX.
High Altitude Pressure Switch Kit
176722600
LPG/Propane Kit
165295202
5” Upward Sloped Cat III Vent Kit
66808903
5” Downward Sloped Cat III Vent Kit
66809003
High Altitude Pressure Switch Kit
176722600
LPG/Propane Kit
165295202
5” Upward Sloped Cat III Vent Kit
66808903
5” Downward Sloped Cat III Vent Kit
66809003
High Altitude Pressure Switch Kit
176722600
LPG/Propane Kit
165295202
5” Upward Sloped Cat III Vent Kit
66808903
5” Downward Sloped Cat III Vent Kit
66809003
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX