MaintainX Asset Hub logo
EnterprisePricing
Advanced Distributor Products

Advanced Distributor Products Unit Heater SEP−115-A

Need answers fast?
Explore the manual using AI.

Advanced Distributor Products Unit Heater SEP−115-A
Advanced Distributor Products Unit Heater SEP−115-A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advanced Distributor Products Unit Heater SEP−115-A

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advanced Distributor Products Unit Heater SEP−115-A

Advanced Distributor Products Unit Heater SEP−115-A

Create an account to install this asset package.

Maintenance Plans for Advanced Distributor Products Unit Heater Model SEP−115-A

Integrate maintenance plans directly into your work orders in MaintainX.

Flue Passageway And Flue Box Maintenance

Check mark

Preparation

Check mark

Turn off both electrical and gas supply to unit

Check mark

Disconnect combustion air inducer wiring

Check mark

Flue Box Removal and Cleaning

Check mark

Remove screws securing flue box to unit

Check mark

Remove flue box

Check mark

Is it necessary to remove blower assembly from flue box?

Check mark

Clean flue box with wire brush

Check mark

Flue Baffles Cleaning

Run this procedureArrow right

2 Yearly Motor Bearing Lubrication

Check mark

Combustion Air Inducer Motor Bearings

Check mark

Verify that combustion air inducer motor bearings are pre-lubricated and sealed

Check mark

Fan Motor Bearings

Check mark

Check for manufacturer's lubrication instructions on each motor

Check mark

Re-lubricate fan motor bearings if no manufacturer's instructions are provided

Check mark

Apply a few drops of SAE No 10 non-detergent oil to motors with oiling ports

Run this procedureArrow right

Combustion Air Inducer Check

Check mark

Preparation

Check mark

Disconnect power supply

Check mark

Inspection and Cleaning

Check mark

Inspect the combustion air inducer for any visible damage or wear

Check mark

Use a small brush to clean the inducer wheel

Check mark

Post-Inspection

Check mark

Is the combustion air inducer clean and free of debris?

Run this procedureArrow right

Heating Sequence Maintenance

Check mark

Initial Checks

Check mark

Verify thermostat calls for heat

Check mark

Check if combustion air inducer starts immediately

Check mark

Combustion Air Pressure Switch

Check mark

Ensure combustion air pressure switch proves inducer operation

Check mark

Confirm no adjustment is necessary for the factory-set switch

Check mark

Ignition and Gas Valve Operation

Check mark

Record prepurge duration in seconds

Check mark

Verify spark ignition is energized

Run this procedureArrow right

Flue And Chimney Check

Check mark

Vent and Vent Connector Inspection

Check mark

Check all vent and vent connector joints for tightness

Check mark

Are all connections sealed?

Check mark

Are there any blockages in the vents?

Check mark

Post Inspection

Check mark

Clean the inspection area

Check mark

Dispose of any debris or waste found during inspection

Run this procedureArrow right

Parts for Advanced Distributor Products Unit Heater SEP−115-A

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

LPG/Propane Kit

165295202

4” Straight Pipe (Length = 6”)

66809301

LPG/Propane Kit

165295202

4” Straight Pipe (Length = 6”)

66809301

LPG/Propane Kit

165295202

4” Straight Pipe (Length = 6”)

66809301

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advanced Distributor Products

Explore Other Assets