Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Single Package Air Conditioner ZF120N24B7A1BAA1A1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Initial 24 Hours Belt Tension Check
Belt Tension Adjustment
Loosen six nuts (top and bottom) A
Adjust by turning (B)
Ensure nuts (C) are not loosened
Use belt tension checker to apply perpendicular force and obtain 4mm deflection distance
Record the deflection force applied
Re-tighten nuts (A) after adjustment
Belt Tension Verification
Enter the number of times belt tension was checked in the first 24 hours
Joints Leaks Check
Safety Precautions
Ensure no open flames are present in the area.
Use only approved pipe dope for assembling pipes.
Gas Connection and Leak Test
Open the main shut-off valve to admit normal gas pressure to the mains.
Check all joints for leaks using a soap solution or other suitable material.
Were any leaks detected during the inspection?
Post-Inspection
Close the main shut-off valve if leaks were detected.
Manifold Gas Pressure Maintenance
Preparation
Turn off all power to the unit
Connect a manometer to the outlet pressure port on the gas valve
Remove plastic cap covering HI and LO pressure adjustment screws
Second Stage Pressure Adjustment
Turn on power to the unit
Set thermostat to call for second stage heat and start furnace
Adjust second stage adjustment screw to set manifold pressure
Is the second stage manifold pressure within 3.5 IWG ± 0.3?
Burner and Orifice Inspection
Ensure main manual shut-off valve is closed and all power to the unit is shut off
Open the union fitting just upstream of the unit gas valve and downstream from the main manual shut-off valve in the gas supply line
Remove the screws holding each end of the manifold to the manifold supports
Disconnect wiring to the gas valves and spark igniters
Remove the manifold & gas valve assembly
Inspect and/or replace orifices
Remove the heat shield on top of the manifold supports
Inspect and/or replace burners
Ensure burners are level and seat at the rear of the gas orifice
Blower Rotation Check
Initial Inspection
Check for proper compressor rotation
Verify blower rotation direction
Electrical Connection Check
Inspect electrical connection for misphasing
Change the phasing of the Field Line Connection if necessary
Scroll Compressor Check
Check if the scroll compressor is drawing low amperage
Check for similar suction and discharge pressures
Access the parts list for your equipment in MaintainX.
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX