Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Heat Pump YHE60
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Heat Pump Maintenance
MAINTENANCE
Dirt accumulation on the outdoor coils or other parts in the air circuit
Use a brush, vacuum cleaner attachment, or other suitable means to clean
The outdoor fan motor bearings are permanently lubricated and do not require periodic oiling
Coil needs to be cleaned
If the coil needs to be cleaned, it should be washed with Calgon Coilclean (mix one part Coilclean to seven parts water). Allow solution to remain on coil for 30 minutes before rinsing with clean water. Solution should not be permitted to come in contact with painted surfaces
Refer to the furnace or air handler instructions for filter and blower motor maintenance
The indoor coil and drain pan should be inspected and cleaned regularly to prevent odors and assure proper drainage
CAUTION: It is unlawful to knowingly vent, release or discharge refrigerant into the open air during repair, service, maintenance or the final disposal of this unit
Heat Pump Charging
CAUTION: Always charge in liquid form. Take care not to slug the compressor.
CAUTION: Compressor damage will occur if system is improperly charged.
CAUTION: Do not leave the system open to the atmosphere. Unit damage could occur due to moisture being absorbed by the POE oil in the system.
WARNING: Do NOT attempt to pump Total System Charge into outdoor unit for maintenance, service, etc. This may cause damage to the compressor and/or other components.
CAUTION: It is unlawful to knowingly vent, release or discharge refrigerant into the open air during repair, service, maintenance or the final disposal of this unit.
CAUTION: Refrigerant charging should only be carried out by a qualified air conditioning contractor.
CAUTION: Compressor damage will occur if system is improperly charged.
Determine outdoor unit factory charge from Tabular Data Sheet
Determine indoor coil adjustment (if any) from Tabular Data Sheet
Heat Pump Pre-start Check
SYSTEM START-UP
ENERGIZE CRANKCASE HEATER
In order to energize the crankcase heater, set the indoor cooling thermostat to the OFF position
Close the line power disconnect to the unit
IMPORTANT: An attempt to start the compressor without at least 8 hours of crankcase heat will damage the compressor
With power to unit and thermostat in cooling position
In the cooling cycle, discharge gas is pumped to the outdoor coil which is the condenser. The indoor coil is the evaporator. Check if this is the case.
If the fan switch is in ON position, a circuit is made through the blower relay to provide continuous blower operation. Is this the case?
With the fan switch in AUTO position, a circuit is made from the thermostat cooling contact through the blower relay to provide blower operation. Is this the case?
Access the parts list for your equipment in MaintainX.
R-410A Filter-Drier
S1-52636219000
R-410A Filter-Drier
S1-52636219000
R-410A Filter-Drier
S1-52636219000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.