MaintainX, an Autodesk company
EnterprisePricing
Viking

Viking Pump K4124A

Need answers fast?
Explore the manual using AI.

Viking Pump K4124A
Viking Pump K4124A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Viking Pump K4124A

Viking Pump K4124A

Create an account to install this asset package.

Maintenance Plans for Viking Pump Model K4124A

Integrate maintenance plans directly into your work orders in MaintainX.

Initial 100 Hours Viking Reducer Oil Change

Check mark

Oil Type Selection

Check mark

Select the oil type based on temperature conditions

Check mark

Oil Quantity Verification

Check mark

Verify the oil quantity for each size

Check mark

Oil Change Procedure

Check mark

Drain the old oil from the reducer

Check mark

Refill with the new lubricant to the proper level

Check mark

Post-Change Verification

Check mark

Is the oil filled to the proper level for the selected size?

Run this procedureArrow right

1000 Hourly Ammonia Pump Reservoir Oil Change

Check mark

Preparation

Check mark

Ensure the pump is turned off and isolated from the power supply

Check mark

Gather necessary tools and materials, including Light Refrigeration Oil and a container for old oil

Check mark

Draining Old Oil

Check mark

Check if the reservoir is empty before draining

Check mark

Place a container under the reservoir to catch old oil

Check mark

Open the drain plug and allow the old oil to completely drain out

Check mark

Refilling Reservoir

Check mark

Measure one pint of Light Refrigeration Oil

Run this procedureArrow right

Initial 200 Hours Ammonia Pump Reservoir Oil Change

Check mark

Preparation

Check mark

Ensure the pump is turned off and isolated from the power source.

Check mark

Gather necessary tools and materials, including Light Refrigeration Oil and a container for old oil.

Check mark

Draining Old Oil

Check mark

Check if the reservoir is empty before starting the procedure.

Check mark

Place a container under the reservoir to catch the old oil.

Check mark

Open the drain plug and allow the old oil to completely drain out.

Check mark

Refilling with New Oil

Check mark

Close the drain plug securely after draining the old oil.

Run this procedureArrow right

Pump Alignment Check

Check mark

CHECK ALIGNMENT AFTER MOUNTING

Check mark

Recheck alignment after the pump unit is installed

Check mark

Check pump ports to ensure they are square and in the proper position

Check mark

Ensure piping is not forced to line up with the ports

Check mark

Flexible Coupling Alignment Check

Check mark

Remove any coupling guards or covers

Check mark

Check alignment of the coupling halves using a straightedge across the coupling

Check mark

V-Belt Alignment Check

Check mark

Check alignment using a long straightedge or tightly drawn string across the face of the sheaves

Run this procedureArrow right

Thrust Bearing Adjustment

Check mark

Initial Adjustment

Check mark

Loosen the two set screws in the outer face of the bearing housing

Check mark

Rotate the bearing housing in a clockwise direction until it cannot be turned any more

Check mark

Marking for Alignment

Check mark

Make a mark on the outside diameter of the bearing housing and a corresponding mark on the pump bracket

Check mark

Make another mark on the pump bracket per 'Table 4' on page 14

Check mark

Final Adjustment

Check mark

Rotate the bearing housing in a counter clockwise direction until the mark on the outside diameter of the bearing housing lines up with the second mark on the pump bracket

Check mark

Check end clearance with feeler gauge between idler and rotor faces, if possible

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Viking

Explore Other Assets