MaintainX, an Autodesk company
EnterprisePricing
Viking

Viking Pump HL1124A

Need answers fast?
Explore the manual using AI.

Viking Pump HL1124A
Viking Pump HL1124A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Viking Pump HL1124A

Viking Pump HL1124A

Create an account to install this asset package.

Maintenance Plans for Viking Pump Model HL1124A

Integrate maintenance plans directly into your work orders in MaintainX.

Pressure Relief Valve Adjustment

Check mark

Pressure Adjustment

Check mark

Remove valve cap covering the adjusting screw

Check mark

Loosen locknut on the adjusting screw

Check mark

Install a pressure gauge in the discharge line

Check mark

Adjust the pressure setting by turning the adjusting screw

Check mark

Close the discharge line beyond the pressure gauge

Check mark

Limit the operation time to prevent rapid temperature rise

Check mark

Record the maximum pressure shown on the gauge

Check mark

Tighten the locknut and replace the cap gasket and valve cap

Run this procedureArrow right

Pump Alignment Check

Check mark

Check Alignment After Mounting

Check mark

Ensure pump, drive, and motor were properly aligned during assembly

Check mark

Recheck alignment after pump unit installation

Check mark

Check pump ports for proper position

Check mark

Shim or move the pump as required

Check mark

Ensure piping is not forced to line up with ports

Check mark

Flexible Coupling Alignment Check

Check mark

Remove any coupling guards or covers

Check mark

Check alignment of coupling halves using a straightedge

Run this procedureArrow right

Pump Packing Adjustment

Check mark

Initial Packing Adjustment

Check mark

Make initial packing adjustments carefully

Check mark

Ensure packing gland is not over-tightened

Check mark

Post-Adjustment Inspection

Check mark

Inspect for leakage control

Check mark

Determine need for packing gland adjustment or replacement

Check mark

Contact Viking Pump® representative for Engineering Service Bulletin ESB-521 regarding repacking pump

Run this procedureArrow right

Pump Cleaning

Check mark

Initial Cleaning

Check mark

Wipe down the exterior of the pump to remove surface dirt and grime

Check mark

Inspect for any visible grease fittings covered in dirt

Check mark

Detailed Cleaning

Check mark

Clean around grease fittings to ensure they are free from dirt

Check mark

Is the pump free from any visible dirt or grease?

Check mark

Post-Cleaning Inspection

Check mark

Inspect the pump for any signs of wear or damage

Check mark

Note any areas that require further inspection or repair

Run this procedureArrow right

500 Hourly Pump Lubrication

Check mark

Lubrication of Pump Fittings

Check mark

Apply multi-purpose grease, NLGI # 2, to all lubrication fittings using a hand gun

Check mark

Record any lubrication issues or observations

Check mark

O-Pro™ Seals Lubrication

Check mark

Grease O-Pro™ seals with a lubricating fluid compatible with the process fluid

Check mark

Record any issues or observations with O-Pro™ seals lubrication

Check mark

Additional Considerations

Check mark

Are there any specific lubrication questions to address with Viking Pump® representative?

Check mark

Does the application involve very high or low temperatures requiring different lubrication?

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Viking

Explore Other Assets