MaintainX Asset Hub logo
EnterprisePricing
SPX Corporation

SPX Corporation Centrifugal Fan RBE-9

Need answers fast?
Explore the manual using AI.

SPX Corporation Centrifugal Fan RBE-9
SPX Corporation Centrifugal Fan RBE-9

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for SPX Corporation Centrifugal Fan RBE-9

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

SPX Corporation Centrifugal Fan RBE-9

SPX Corporation Centrifugal Fan RBE-9

Create an account to install this asset package.

Maintenance Plans for SPX Corporation Centrifugal Fan Model RBE-9

Integrate maintenance plans directly into your work orders in MaintainX.

Safety Equipment and Accessories Inspection

Check mark

Safety Guards Inspection

Check mark

Ensure all safety guards are properly attached and fully functional

Check mark

Is the power to the blower turned off and locked-out if any guards are defective?

Check mark

Accessories Inspection

Check mark

Inspect accessories for proper function within intended limits and design specifications

Check mark

Refer to manufacturer's maintenance manuals for correct maintenance procedures

Check mark

Post-Inspection Actions

Check mark

Have all defective parts been repaired or replaced?

Check mark

Have repairs and replacements been inspected by authorized personnel?

Run this procedureArrow right

Electric Motor Lubrication

Check mark

Preparation

Check mark

Ensure motor is turned off and locked out

Check mark

Verify that the motor has grease fittings

Check mark

Lubrication Process

Check mark

Select the appropriate grease based on manufacturer recommendations

Check mark

Enter the motor horsepower

Check mark

Enter the motor speed (RPM)

Check mark

Is the grease compatible with the motor?

Check mark

Remove grease plugs and replace with grease fittings if necessary

Run this procedureArrow right

1 Yearly Vibration Check

Check mark

Pre-Check Preparation

Check mark

Ensure all routine maintenance is completed

Check mark

Vibration Reading

Check mark

Record new vibration readings

Check mark

Are the new readings within acceptable limits compared to initial startup readings?

Check mark

Problem Identification

Check mark

Identify potential causes of vibration problems

Check mark

Describe any identified issues and corrective actions taken

Check mark

Post-Check Actions

Run this procedureArrow right

Blower Bearing Lubrication

Check mark

Preparation

Check mark

Ensure the following conditions are met before lubrication

Check mark

Lubrication Process

Check mark

Is the application in a high temperature environment requiring special grease?

Check mark

Select the type of grease to be used

Check mark

Use a hand-operated grease gun at no more than 40 psi

Check mark

Is it possible to lubricate the blower bearings while the blower is running?

Check mark

Enter the number of grease shots applied (1-2 recommended)

Check mark

Did a slight bead of grease appear at the bearing seals?

Run this procedureArrow right

Blower Shaft and Bearing Replacement

Check mark

Preparation

Check mark

Lock out the power source to the motor and let the wheel come to a complete stop.

Check mark

Disconnect the inlet and/or discharge duct work from the blower, if necessary.

Check mark

Disassembly

Check mark

Remove the inlet side of the blower housing.

Check mark

Measure and record the location of the blower wheel on the shaft.

Check mark

Remove the locking hardware in the wheel hub and carefully remove the wheel.

Check mark

Remove guards and loosen components

Check mark

Remove the belt(s) and blower sheave.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from SPX Corporation

Explore Other Assets