MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Air Conditioner PLA-RP125BA

Need answers fast?
Explore the manual using AI.

Mitsubishi Air Conditioner PLA-RP125BA
Mitsubishi Air Conditioner PLA-RP125BA

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Air Conditioner PLA-RP125BA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Air Conditioner PLA-RP125BA

Mitsubishi Air Conditioner PLA-RP125BA

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Air Conditioner Model PLA-RP125BA

Integrate maintenance plans directly into your work orders in MaintainX.

Panel Disassemble

Check mark

Remove the air intake grille and the filter

Check mark

Disconnect the connector CNV (White/20P)

Check mark

Remove the corner screw

Check mark

Slide the corner panel to the direction of the arrow 1, and remove the corner panel

Check mark

Remove the 2 screws from the panel which fix to the oval holes

Check mark

Rotate the panel a little to come to the bell shaped hole where the screw is large and remove the panel

Run this procedureArrow right

TH1 Thermistor Disassemble

Check mark

Remove the air intake grille and the filter

Check mark

Remove the 2 screws from the electrical box

Check mark

Disconnect the connector CN20 (Red) from the indoor controller board

Check mark

Remove the room temperature thermistor and holder

Run this procedureArrow right

TH2 and TH5 Disassemble

Check mark

Remove the drain pan

Check mark

Upload a photo of the removed drain pan

Check mark

Remove the turbo fan

Check mark

Upload a photo of the removed turbo fan

Check mark

Remove the 2 wiring clamps

Check mark

Upload a photo of the removed wiring clamps

Check mark

Remove the coil plate (2 screws)

Check mark

Remove the thermistors which are inserted into the holders installed to the thin copper pipe

Check mark

Disconnect the 4-pin white connector (CN44)

Run this procedureArrow right

Drain Pump and Float Switch Disassemble

Check mark

Remove the drain pan

Check mark

Upload a photo of the removed drain pan

Check mark

Cut the hose band and remove the hose

Check mark

Remove the drain pump assembly (3 screws and 2 hooks)

Check mark

Remove the drain pump (3 screws)

Check mark

Remove the float switch (2 screws)

Check mark

Sign off on the disassembly process

Run this procedureArrow right

Indoor Controller Board Disassemble

Check mark

Remove the air intake grille and the filter

Check mark

Remove the 2 screws from the electrical box cover

Check mark

Disconnect the connectors

Check mark

Remove the 6 supports from indoor controller board

Check mark

Remove the indoor controller board

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets