Liger Medical Hydrotherapy Unit HTU-110
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Handle / Battery Cleaning
Disassemble the TC
Ensure all parts are separated
Cleaning the TC Handle and Battery
Prepare cleaning solution on a damp cloth
Wipe all surfaces of the TC handle and battery thoroughly
Ensure no fluids enter the device
Confirm no sterilization of the TC handle or battery
3 Monthly Hydrotherapy Unit Inspection
Pre-Use Inspection
Inspect for visible damage
Ensure no parts are missing or loose
Check that all connecting elements between instruments function properly
Battery Handling
Insert a charged battery into the handle of the device
Did the battery lock into place with a snap?
Device Verification
Verify that the TC and accessories are in good working order by following the 'Using the Device' steps
Manual Cleaning
Preparation
Ensure all equipment is available
Place silicone cap on probe connector
Initial Rinse
Rinse probe shaft using cool running water
Use tools to aid in soil removal
Is water running clear from the shaft?
Detergent Preparation and Soaking
Prepare enzymatic detergent as per manufacturer’s recommendations
Probe Cleaning
Pre-Cleaning Preparation
Allow the probe tip to cool to room temperature before cleaning.
Clean instrument within 30 minutes of completing a treatment.
Cleaning Process
Place silicone cap on probe connector to prevent liquid ingress to the connector.
Ensure no abrasive materials are used during cleaning.
Describe the cleaning method used.
Post-Cleaning
Was additional sterilization or high level disinfection (HLD) processing completed?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.