MaintainX Asset Hub logo
EnterprisePricing
Pentair

Pentair Cartridge Filter CCP520

Need answers fast?
Explore the manual using AI.

Pentair Cartridge Filter CCP520
Pentair Cartridge Filter CCP520

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Pentair Cartridge Filter CCP520

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Pentair Cartridge Filter CCP520

Pentair Cartridge Filter CCP520

Create an account to install this asset package.

Maintenance Plans for Pentair Cartridge Filter Model CCP520

Integrate maintenance plans directly into your work orders in MaintainX.

Air Relief Valve Cleaning

Check mark

Preparation

Check mark

Turn off the pump and shut off any automatic controls

Check mark

Disconnect power at the circuit breaker

Check mark

Open the Manual Air Relief Valve by turning the top 1/4 turn counterclockwise

Check mark

Is the pressure gauge reading zero (0) psi?

Check mark

Valve Disassembly

Check mark

Pull out the locking tabs and unlock the valve stem and cover assembly from the valve body counter-clockwise

Check mark

Pull the valve stem and cover assembly away from the valve body

Check mark

Cleaning and Inspection

Run this procedureArrow right

Pressure Gauge Maintenance

Check mark

Pressure Gauge Inspection

Check mark

Record the current pressure reading on the gauge

Check mark

Is the pressure gauge reading zero (0) psi after pressure is relieved?

Check mark

Does the pressure gauge indicate pressure when the system is operating?

Check mark

Is the pressure gauge readable and undamaged?

Check mark

Pressure Gauge Replacement

Check mark

Replace the pressure gauge (P/N 190058) if any of the above conditions are not met

Check mark

Post Maintenance

Check mark

Ensure the new pressure gauge is properly installed and secured

Run this procedureArrow right

Filter Cartridges Acid Cleaning

Check mark

Preparation

Check mark

Remove all oils and cleaning solutions from the cartridges

Check mark

Put on protective equipment - rubber gloves, safety glasses and N-95 dust mask

Check mark

Acid Solution Preparation

Check mark

Create a solution of one part muriatic acid to twenty parts water in a large plastic container

Check mark

Introduce the muriatic acid as close to the water's surface as possible to minimize splash

Check mark

Cartridge Soaking

Check mark

Gently place the bottom of the cartridges into the acid solution and soak for 10 minutes or until bubbling stops

Check mark

Turn the cartridges over and soak the top halves for 10 minutes or until bubbling stops

Run this procedureArrow right

Filter Cartridges Cleaning

Check mark

Determine When to Clean the Filter

Check mark

Enter the current pressure reading from the pressure gauge

Check mark

Is the pressure reading approximately 10 psi higher than the 'Original Starting Pressure'?

Check mark

Is there a significant reduction in flow?

Check mark

Opening the Filter

Check mark

Shut off pump and relieve all pressure from the filtration system

Check mark

Open the Manual Air Relief Valve

Check mark

Ensure pressure gauge reads zero (0) psi

Check mark

Open the drain plug and allow all water to drain from the filter

Run this procedureArrow right

3 Yearly Filter Cartridge Replacement

Check mark

Opening the Filter

Check mark

Shut off pump and relieve all pressure from the filtration system

Check mark

Open the Manual Air Relief Valve

Check mark

Ensure pressure gauge reads zero (0) psi

Check mark

Open the drain plug at the bottom of the filter and allow all water to drain

Check mark

Loosen the clamp barrel nut using a 7/8-inch wrench

Check mark

Remove the barrel nut, spring, and two washers from the T-bolt

Check mark

Remove the clamp ring from the filter

Check mark

Carefully lift the filter lid away from the tank bottom

Run this procedureArrow right

Parts for Pentair Cartridge Filter CCP520

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Pressure Gauge

190058

Manual Air Relief Valve

98209800

Compression Spring

178616

Top Manifold, C&C 320/420/520

170027

Cartridge, C&C 520, Single Cartridge

PCC130

Pressure Gauge

190058

Manual Air Relief Valve

98209800

Compression Spring

178616

Top Manifold, C&C 320/420/520

170027

Cartridge, C&C 520, Single Cartridge

PCC130

Pressure Gauge

190058

Manual Air Relief Valve

98209800

Compression Spring

178616

Top Manifold, C&C 320/420/520

170027

Cartridge, C&C 520, Single Cartridge

PCC130

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Pentair

Explore Other Assets