Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Pentair Cartridge Filter CCP420
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Relief Valve Cleaning
Preparation
Turn off the pump and shut off any automatic controls
Disconnect power at the circuit breaker
Open the Manual Air Relief Valve by turning the top 1/4 turn counterclockwise
Ensure pressure gauge reads zero (0) psi
Valve Disassembly
Pull out the locking tabs and unlock the valve stem and cover assembly from the valve body counter-clockwise
Pull the valve stem and cover assembly away from the valve body
Cleaning and Inspection
Filter Cartridges Acid Cleaning
Preparation
Remove all oils and cleaning solutions from the cartridges
Put on protective equipment - rubber gloves, safety glasses and N-95 dust mask
Acid Solution Preparation
Create a solution of one part muriatic acid to twenty parts water in a large plastic container
Introduce the muriatic acid as close to the water's surface as possible to minimize splash
Cartridge Soaking
Gently place the bottom of the cartridges into the acid solution and soak for 10 minutes or until bubbling stops
Turn the cartridges over and soak the top halves for 10 minutes or until bubbling stops
Pressure Gauge Maintenance
Pressure Gauge Inspection
Record the current pressure reading on the gauge
Is the pressure gauge reading zero (0) psi after pressure is relieved?
Does the pressure gauge indicate pressure when the system is operating?
Is the pressure gauge readable and undamaged?
Pressure Gauge Replacement
Replace the pressure gauge (P/N 190058) if any of the above conditions are not met
Post Maintenance
Ensure the new pressure gauge is properly installed and secured
Filter Cartridges Cleaning
Determine When to Clean the Filter
Enter the current pressure reading from the pressure gauge
Is the pressure reading approximately 10 psi higher than the 'Original Starting Pressure'?
Opening the Filter
Shut off pump and relieve all pressure from the filtration system
Open the Manual Air Relief Valve
Ensure pressure gauge reads zero (0) psi
Open the drain plug and allow all water to drain from the filter
Loosen the clamp barrel nut using a 7/8-inch wrench
3 Yearly Filter Cartridge Replacement
Opening the Filter
Shut off pump and relieve all pressure from the filtration system
Open the Manual Air Relief Valve by turning the top of the valve 1/4 turn counterclockwise until it snaps into the full open position.
Stand clear of the filter and wait until all pressure is relieved. Pressure gauge must read zero (0) psi.
Open the drain plug at the bottom of the filter and allow all water to drain from the filter.
Using a 7/8-inch wrench, loosen the clamp barrel nut, allowing the spring coils to decompress.
Remove the following components and place them aside
Remove the clamp ring from the filter and place it aside.
Carefully lift the filter lid away from the tank bottom. DO NOT lift the filter lid by the air relief valve.
Access the parts list for your equipment in MaintainX.
Pressure Gauge
190058
Manual Air Relief Valve
98209800
Compression Spring
178616
Top Manifold, C&C 320/420/520
170027
Cartridge, C&C 420, Single Cartridge
PCC105
Pressure Gauge
190058
Manual Air Relief Valve
98209800
Compression Spring
178616
Top Manifold, C&C 320/420/520
170027
Cartridge, C&C 420, Single Cartridge
PCC105
Pressure Gauge
190058
Manual Air Relief Valve
98209800
Compression Spring
178616
Top Manifold, C&C 320/420/520
170027
Cartridge, C&C 420, Single Cartridge
PCC105
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX