MaintainX Asset Hub logo
EnterprisePricing
Leybold

Leybold Vacuum Pump TRIVAC S 65 B 113 55

Need answers fast?
Explore the manual using AI.

Leybold Vacuum Pump TRIVAC S 65 B 113 55
Leybold Vacuum Pump TRIVAC S 65 B 113 55

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Leybold Vacuum Pump TRIVAC S 65 B 113 55

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Leybold Vacuum Pump TRIVAC S 65 B 113 55

Leybold Vacuum Pump TRIVAC S 65 B 113 55

Create an account to install this asset package.

Maintenance Plans for Leybold Vacuum Pump Model TRIVAC S 65 B 113 55

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Fan and Cooling Fins Cleaning

Check mark

3.10 Maintenance Plan

Check mark

Check for deposits

Check mark

Clean deposits using brush and industrial vacuum cleaner

Check mark

Was the pump or motor cleaned before the maintenance interval due to overheating?

Check mark

Switch off the pump and disconnect from the mains to prevent inadvertent startup

Run this procedureArrow right

Pump Module Maintenance

Check mark

3.7 Removing and Remounting the Pump Module

Check mark

Ensure all required tools are available

Check mark

Ensure all required spare parts are available

Check mark

3.7.1 Removing the Pump Module

Check mark

Drain the oil and remove the oil case (see Section 3.4)

Check mark

Unscrew the hex. nuts (13/1)

Check mark

Pull the entire pump module (13/2) forward off the tie rods (13/5)

Check mark

Ensure individual pin-fitted parts are not loosened

Check mark

Remove the gasket (13/3)

Run this procedureArrow right

6 Monthly Dirt Trap Cleaning

Check mark

3.3 Cleaning the Dirt Trap

Check mark

Remove the dirt trap from the intake port

Check mark

Rinse the dirt trap in a suitable vessel with solvent

Check mark

Thoroughly dry the dirt trap with compressed air

Check mark

Check if the dirt trap is defective

Check mark

Replace the dirt trap if defective

Check mark

Ensure the cleaning agent complies with national/international specifications

Check mark

Observe safety regulations when using cleaning agents

Run this procedureArrow right

Electric Motor Assembly/Disassembly

Check mark

3.5 Disassembly and Reassembly of the Electric Motor

Check mark

Ensure safety precautions are followed

Check mark

Disconnect the motor from the mains

Check mark

Prevent the pump from running up

Check mark

Gather required tools

Check mark

Disassembly steps

Check mark

Support the motor

Check mark

Unscrew the four non-recessed hex. socket screws (11/5)

Check mark

Remove the intermediate flange (11/4) together with the electric motor

Run this procedureArrow right

2 Yearly Pump Maintenance

Check mark

3.10 Maintenance Plan

Check mark

Clean the pump thoroughly

Check mark

Check individual components

Check mark

Exchange all seals

Check mark

Perform functional check

Check mark

Ensure the check is run by Leybold service

Run this procedureArrow right

Parts for Leybold Vacuum Pump TRIVAC S 65 B 113 55

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Leybold

Explore Other Assets