MaintainX Asset Hub logo
EnterprisePricing
Leybold

Leybold Vacuum Pump TRIVAC D 40 B 112 96

Need answers fast?
Explore the manual using AI.

Leybold Vacuum Pump TRIVAC D 40 B 112 96
Leybold Vacuum Pump TRIVAC D 40 B 112 96

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Leybold Vacuum Pump TRIVAC D 40 B 112 96

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Leybold Vacuum Pump TRIVAC D 40 B 112 96

Leybold Vacuum Pump TRIVAC D 40 B 112 96

Create an account to install this asset package.

Maintenance Plans for Leybold Vacuum Pump Model TRIVAC D 40 B 112 96

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Pump Oil Level Check

Check mark

3.1 Checking the Oil Level

Check mark

Ensure the oil level is between the marks on the oil-level glass

Check mark

Is the oil level adequate?

Check mark

Top up the oil if required

Check mark

3.10 Maintenance Plan

Check mark

Check if the oil needs to be changed

Check mark

Select the type of oil used for refill

Check mark

Refill oil only after the pump has been switched off

Check mark

3.1.1 Checking the Condition of N 62 or HE 200 Oil

Run this procedureArrow right

6 Monthly Dirt Trap Cleaning

Check mark

3.3 Cleaning the Dirt Trap

Check mark

Ensure the following precautions are taken

Check mark

Remove the dirt trap from the intake port

Check mark

Rinse the dirt trap in a suitable vessel with solvent

Check mark

Thoroughly dry the dirt trap with compressed air

Check mark

Is the dirt trap defective?

Check mark

Replace the dirt trap if defective

Run this procedureArrow right

2000 Hourly / 1 Yearly Pump Oil Change

Check mark

3.2 Oil Change

Check mark

Safety Precautions

Check mark

Ensure all necessary safety precautions are taken if the operating agent may present a hazard due to decomposition of the oil or the media pumped.

Check mark

Oil Drain Process

Check mark

Switch off the pump and ensure it is still warm before proceeding.

Check mark

Remove the oil-drain plug (9/4) and let the used oil drain into a suitable container.

Check mark

Screw the oil-drain plug back in, briefly switch on the pump (max. 10 s) and then switch it off again.

Check mark

Remove the oil-drain plug once more and drain out the remaining oil.

Check mark

Screw the oil-drain plug back in (check the gasket and reinstall a new one if necessary).

Run this procedureArrow right

Pump Module Maintenance

Check mark

3.7 Removing and Remounting the Pump Module

Check mark

Ensure all required tools are available

Check mark

Ensure all required spare parts are available

Check mark

3.7.1 Removing the Pump Module

Check mark

Drain the oil and remove the oil case (see Section 3.4)

Check mark

Unscrew the hex. nuts (13/1)

Check mark

Pull the entire pump module (13/2) forward off the tie rods (13/5)

Check mark

Ensure individual pin-fitted parts are not loosened

Check mark

Remove the gasket (13/3)

Run this procedureArrow right

1 Yearly Fan and Cooling Fins Cleaning

Check mark

3.10 Maintenance Plan

Check mark

Switch off the pump and disconnect from the mains to ensure it cannot run inadvertently.

Check mark

Check for deposits and clean as required

Check mark

Use a brush to clean the deposits.

Check mark

Use an industrial vacuum cleaner to remove any remaining debris.

Run this procedureArrow right

Parts for Leybold Vacuum Pump TRIVAC D 40 B 112 96

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Leybold

Explore Other Assets