MaintainX Asset Hub logo
EnterprisePricing
Leybold

Leybold Vacuum Pump TRIVAC D 65 B 103 56

Need answers fast?
Explore the manual using AI.

Leybold Vacuum Pump TRIVAC D 65 B 103 56
Leybold Vacuum Pump TRIVAC D 65 B 103 56

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Leybold Vacuum Pump TRIVAC D 65 B 103 56

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Leybold Vacuum Pump TRIVAC D 65 B 103 56

Leybold Vacuum Pump TRIVAC D 65 B 103 56

Create an account to install this asset package.

Maintenance Plans for Leybold Vacuum Pump Model TRIVAC D 65 B 103 56

Integrate maintenance plans directly into your work orders in MaintainX.

Pump Storage Maintenance

Check mark

3.9 Storing the Pump

Check mark

Store the pump in a dry place at room temperature (20 °C)

Check mark

Properly disconnect the pump from the vacuum system

Check mark

Purge the pump with dry nitrogen

Check mark

Change the oil in the pump

Check mark

Seal the inlets and outlets with shipping seals

Check mark

Set the gas ballast switch to the '0' position

Check mark

Seal the pump in a PE bag with desiccant if shelved for a long period

Check mark

Run standard maintenance if the pump has been shelved for over one year

Run this procedureArrow right

2 Yearly Pump Maintenance

Check mark

3.10 Maintenance Plan

Check mark

Clean the pump thoroughly

Check mark

Check individual components

Check mark

Exchange all seals

Check mark

Perform functional check

Check mark

Ensure the check is run by the Leybold service

Run this procedureArrow right

2000 Hourly / 1 Yearly Pump Oil Change

Check mark

3.2 Oil Change

Check mark

Safety Precautions

Check mark

Ensure all necessary safety precautions are taken if the operating agent may present a hazard due to decomposition of the oil or the media pumped.

Check mark

Oil Drain Process

Check mark

Switch off the pump and ensure it is still warm before proceeding.

Check mark

Remove the oil-drain plug (9/4) and let the used oil drain into a suitable container.

Check mark

Screw the oil-drain plug back in, briefly switch on the pump (max. 10 s) and then switch it off again.

Check mark

Remove the oil-drain plug once more and drain out the remaining oil.

Check mark

Screw the oil-drain plug back in (check the gasket and reinstall a new one if necessary).

Run this procedureArrow right

6 Monthly Internal Demister Cleaning

Check mark

3.4 Removing and Fitting the Internal Demister

Check mark

Ensure all required tools and spare parts are available

Check mark

Shutdown the pump and drain the oil (see Section 3.2)

Check mark

Remove the six recessed screws (10/6) on the oil case (10/4)

Check mark

Pull the oil case forward off the pump

Check mark

Remove the gasket (10/5)

Check mark

Unscrew screw (10/1)

Check mark

Remove the following components

Check mark

Lift off the frame (10/2) and remove the internal demister (10/3)

Run this procedureArrow right

Pump Module Maintenance

Check mark

3.7 Removing and Remounting the Pump Module

Check mark

Ensure all required tools are available

Check mark

Ensure all required spare parts are available

Check mark

3.7.1 Removing the Pump Module

Check mark

Drain the oil and remove the oil case (see Section 3.4)

Check mark

Unscrew the hex. nuts (13/1)

Check mark

Pull the entire pump module (13/2) forward off the tie rods (13/5)

Check mark

Ensure individual pin-fitted parts are not loosened

Check mark

Remove the gasket (13/3)

Run this procedureArrow right

Parts for Leybold Vacuum Pump TRIVAC D 65 B 103 56

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Oil N 62 1l

177 01

Oil N 62 5l

177 02

Oil N 62 20l

177 03

Oil HE-200 1 Qt

98 198 006

Oil HE-200 12 Qt Case

98 198 049

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Leybold

Explore Other Assets