The Hussmann Merchandiser IM-05-10R is a high-quality refrigeration unit designed for optimal product display and preservation. This model features advanced temperature control and energy-efficient components, making it ideal for retail environments. Enhance your merchandising strategy with this reliable asset from Hussmann.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Hussmann Merchandiser IM-05-10R
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Case Cleaning
• Long life and satisfactory performance of any equipment are dependent upon the care given to it. To insure long life, proper sanitation and minimum maintenance costs, the refrigerator should be thoroughly cleaned frequently.
• SHUT OFF FAN DURING CLEANING PROCESS. It can be unplugged within the case, or shut off entire case at the source. The interior bottom may be cleaned with any domestic soap or detergent based cleaners.
• Sanitizing solutions will not harm the interior bottom, however, these solutions should always be used according to the Hussmann’s directions.; It is essential to establish and regulate cleaning procedures. This will minimize bacteria causing discoloration which leads to degraded product appearance and significantly shortening product shelf life.
• Soap and hot water are not enough to kill this bacteria. A sanitizing solution must be included with each cleaning process to eliminate this bacteria.
- Cases Without Sump Pumps
1. Scrub thoroughly, cleaning all surfaces, with soap and hot water.
2. Rinse with hot water, but do not flood.
3. Apply the sanitizing solution according to Hussmann’s directions.
4. Rinse thoroughly.
Coils Cleaning
Warning: Never use sharp objects around coils. Use a soft brush or vacuum brush to clean debris from coils.
Warning: Do not puncture coils! Do not bend fins.
Contact an authorized service technician if a coil is punctured, cracked, or otherwise damaged.
Do NOT use chlorine or ammonia-based cleaners to clean aluminum coils.
Is there ICE in or on the coil?
Contact an authorized service technician to determine the cause of icing, and to make adjustments as necessary.
To maintain product integrity, move all product to a cooler until the unit has returned to normal operating temperatures.
Sign off on the coils cleaning
Glass and Mirrors Cleaning
- Only use a soft cloth and mild glass cleaner for cleaning any glass or mirrored components. Be sure to rinse and/ or dry completely.
* Never use hot water on cold glass surfaces! It may shatter and cause serious injury! Allow glass surfaces to warm first.
CLEANING PRECAUTIONS
When cleaning: • Do not use high pressure water hoses
• Do not introduce water faster then waste outlet can drain
• NEVER INTRODUCE WATER ON SELF CONTAINED UNIT WITH AN EVAPORATOR FAN
• NEVER USE A CLE NIN OR SANITIZING SOLUTION THAT HAS AN OIL BASE (these will dissolve the butyl sealants) or an AMMONIA BASE (this will corode the copper components of the case)
• TO PRESERVE THE ATTRACTIVE FINISH:
• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY
Fluorescent Lamps Replacement
DANGER! BEFORE SERVICING! ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters Thermostats, and Lights.
CAUTION! Fluorescent Lamps contain mercury vapor. Mercury exposure at high levels can harm the brain, heart, kidneys, lungs and immune system of people of all ages. Do not break or puncture fluorescent lamps. Dispose of, or store, all fluorescent lamps in accordance with Federal (40 CFR 273), State and local hazardous waste requirements.
Fluorescent lamps are furnished with a shatterproof protective coating.
The same type of lamp with protective coating must be used if replaced.
Sign off on the lamp replacement procedure
Evaporator Fan Maintenance
DANGER! BEFORE SERVICING! ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters Thermostats, and Lights.
The evaporator fans are located at the center front of these merchandisers directly beneath the display pans.
Is the fan operational?
Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.
Upload a photo of the replaced fan
Sign off on the fan maintenance
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX