Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Hitachi Oil Free Scroll Compressor SRL-16.5M6LL

Hitachi Oil Free Scroll Compressor SRL-16.5M6LL

Create an account to install this asset package.

Maintenance Plans for Hitachi Oil Free Scroll Compressor Model SRL-16.5M6LL

Integrate maintenance plans directly into your work orders in MaintainX.

Compressor Storage Maintenance

Check mark

Monthly Maintenance

Check mark

Idle the air compressor for longer than 30 minutes

Check mark

Six-Month Maintenance

Check mark

Operate the air compressor in a no-load state for 10 minutes

Check mark

Increase the pressure of the air compressor to verify correct operation

Check mark

Operate the air compressor for another 10 minutes in a no-load state before stopping

Check mark

Completely drain the condensate in the air receiver

Check mark

Storage Location

Check mark

Select the storage area for the air compressor

Run this procedureArrow right

10000 Hours / 4 Yearly Compressor Maintenance

Check mark

Replacement of Parts

Check mark

Replace Tip seal and Face seal

Check mark

Grease the scroll bearing

Check mark

Replace Check valve

Check mark

Replace components

Check mark

Cleaning Tasks

Check mark

Clean the dirt off these components

Check mark

Clean the dirt off or replace Coolers

Check mark

Inspection Tasks

Run this procedureArrow right

2500 Hours / 1 Yearly Compressor Maintenance

Check mark

Safety Precautions

Check mark

Press the STOP switch and turn off the main power supply

Check mark

Open all the valves to ensure no residual pressure remains

Check mark

Wait at least 30 minutes before performing the inspection and cleaning

Check mark

Wear proper protection

Check mark

Intake Air Filter Maintenance

Check mark

Replace a dirty or clogged Intake Air filter

Check mark

Was the intake air filter replaced?

Check mark

Rubber Hose Inspection

Run this procedureArrow right

20000 Hours / 8 Yearly Compressor Maintenance

Check mark

Filter and Component Cleaning

Check mark

Replace Intake Air filter if dirty or clogged

Check mark

Clean the dirt off these components

Check mark

Scroll Bearing and Head Maintenance

Check mark

Grease or inspect the scroll bearing

Check mark

Replace the scroll head if there is any damage with bearing

Check mark

Seal Replacement

Check mark

Replace Tip seal

Check mark

Replace Face seal

Run this procedureArrow right

1 Daily Safety Relief Valve Inspection

Check mark

Initial Setup

Check mark

Open the front door of the air compressor

Check mark

Safety Precautions

Check mark

Wear earplugs to protect against discharge noise

Check mark

Wear protection glasses to guard against dust

Check mark

Safety Relief Valve Inspection

Check mark

Verify that the safety relief valve is operating properly by lightly pulling the spindle when the air compressor is near maximum pressure (122psig or 145psig)

Check mark

Ensure that the safety relief valve does not operate below the maximum pressure

Check mark

Post-Inspection Actions

Run this procedureArrow right

Parts for Hitachi Oil Free Scroll Compressor SRL-16.5M6LL

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Intake Air Filter

758334

Intake Air Filter Gasket

741227

Check Valve

742044

Safety Relief Valve For 122psig

742323

Safety Relief Valve For 145psig

742324

Intake Air Filter

758334

Intake Air Filter Gasket

741227

Check Valve

742044

Safety Relief Valve For 122psig

742323

Safety Relief Valve For 145psig

742324

Intake Air Filter

758334

Intake Air Filter Gasket

741227

Check Valve

742044

Safety Relief Valve For 122psig

742323

Safety Relief Valve For 145psig

742324

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Hitachi

Explore Other Assets