

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Hill-Rom Electric Hospital Bed Advanta
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Control Cover Removal
Turn off the air system power at the footboard
Remove the mattress from the bed
Raise the bed to the high position using the hilow function
SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage
Unplug the bed from its power source
Using the T25 Torx® head screwdriver, loosen the screws (A) securing the seat section panel (B) to the bed frame
CAUTION: If your bed is equipped with the Patient Position Monitor, do not set heavy objects directly on the pressure switches. Damage can occur to the pressure switches
Place the seat section panel (B) to one side, not on the pressure switches
Remove the screws (C) securing the air control cover (D) to the bed, and remove the air control cover (D) from the bed
Air Sleep Surface - Air Control P.C. Board Removal
Raise the bed to the high position using the hilow function.
SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage.
Unplug the bed from its power source.
Remove the mattress from the bed (see “Air Sleep Surface Mattress” on page 4-17).
Remove the seat section panel and air control cover from the bed (see “Air Control Cover” on page 4-15).
Disconnect the connectors (A) going to the air control P.C. board (C) (see figure 4-9 on page 4-26).
Using the small flat head screwdriver, remove the two screw locks (D) on the connector.
CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. boards by their edges.
CAUTION: When handling electronic components, wear an antistatic strap. Failure to do so, could result in component damage.
Air Sleep Surface - Compressor Removal
Raise the bed to the high position using the hilow function.
SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage.
Unplug the bed from its power source.
Remove the mattress from the bed (see “Air Sleep Surface Mattress” on page 4-17).
Remove the seat section panel and air control cover from the bed (see “Air Control Cover” on page 4-15).
Using the small flat head screwdriver, remove the two screw locks (D) on the connector (A) (see figure 4-12 on page 4-35).
Disconnect the connector (A) going from the air control P.C. board.
Using the T25 Torx®1 head screwdriver, remove the screw (B) securing the air system weld assembly to the frame of the bed.
Carefully lift up the air system weld assembly (C) and place it on the thigh section of the sleep surface.
Air Sleep Surface - Compressor Replacement
CAUTION: Attach the large air hose to the air sleep surface compressor with a cable tie. If the hose becomes unattached during operation, equipment damage could occur.
Compressor installed in the reverse order of removal
Large air hose attached to the air sleep surface compressor with a cable tie
Function checks performed as per page 2-6
Sign off on the compressor replacement
Air Sleep Surface Mattress Removal
SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage.
Unplug the bed from its power source.
Lift the foot section (B) to access the air hose coupling (D) and cable connector (C) (see figure 4-6 on page 4-17).
Depress the air hose coupling (D) to disconnect the mattress air hose from the bed.
Disconnect the cable connector (C).
Disconnect the plastic buckle (E) holding the mattress in place.
Remove the mattress (A) from the bed.
Sign off on the mattress removal
Access the parts list for your equipment in MaintainX.
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
10-32 Keps Nut
40497 (1600)
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













