MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA
Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model PUHZ-RP140VKA

Integrate maintenance plans directly into your work orders in MaintainX.

Outdoor Unit 4-Way Valve Coil (21S4), and LEV Coil (LEV (A), LEV (B)), (LEV (C) Replacement

Check mark

(1) Remove the service panel. (See Photo 1)

Check mark

(2) Remove the top panel. (See Photo 1)

Check mark

[Removing the 4-way valve coil]

Check mark

(3) Remove 4-way valve coil fixing screw (M4 × 6).

Check mark

(4) Remove the 4-way valve coil by sliding the coil toward you.

Check mark

(5) Disconnect the connector 21S4 (green) on the controller circuit board in the electrical parts box.

Check mark

[Removing the LEV coil]

Check mark

(3) Remove the LEV coil by sliding the coil upward.

Check mark

(4) Disconnect the connectors, LEV A (white) and LEV B (red), LEV C (blue) on the controller circuit board in the electrical parts box.;

Run this procedureArrow right

Outdoor Unit 4-Way Valve Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the electrical parts box

Check mark

Upload a photo of the removed electrical parts box

Check mark

Remove 3 valve bed fixing screws and 4 ball valve and stop valve fixing screws then remove the valve bed

Check mark

Remove 3 right side panel fixing screws in the rear of the unit then remove the right side panel

Check mark

Remove the 4-way valve coil

Run this procedureArrow right

Outdoor Unit Compressor (MC) Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove 2 front cover panel fixing screws (5 × 10) and remove the front cover panel

Check mark

Upload a photo of the removed front cover panel

Check mark

Remove 4 back cover panel fixing screws (5 × 10) and remove the back cover panel

Check mark

Remove the electrical parts box

Check mark

Upload a photo of the removed electrical parts box

Run this procedureArrow right

Outdoor Unit Electrical Parts Box Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Disconnect the indoor/outdoor connecting wire from terminal block

Check mark

Remove all the following connectors from controller circuit board

Check mark

Pull out the disconnected wire from the electrical parts box

Check mark

Remove the terminal cover and disconnect the compressor lead wire

Check mark

Remove 2 electrical parts box fixing screws (4 × 10) and detach the electrical parts box by pulling it upward

Run this procedureArrow right

Outdoor Unit Fan Motor (MF1, MF2) Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove 4 fan grille fixing screws (5 × 10) to detach the fan grille

Check mark

Upload a photo of the detached fan grille

Check mark

Remove a nut (for right handed screw of M6) to detach the propeller

Check mark

Upload a photo of the detached propeller

Check mark

Disconnect the connectors, CNF1, CNF2 on controller circuit board in electrical parts box

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP140VKA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type, Hermetic Compressor - 2,9 KW

ANB42FDWMT

Inverter Starter Type, Hermetic Compressor - 2,9 KW

ANB42FDWMT

Inverter Starter Type, Hermetic Compressor - 2,9 KW

ANB42FDWMT

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets