MaintainX Asset Hub logo
EnterprisePricing
Hill-Rom

Hill-Rom Birthing Bed P3700

Need answers fast?
Explore the manual using AI.

Hill-Rom Birthing Bed P3700
Hill-Rom Birthing Bed P3700

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Hill-Rom Birthing Bed P3700

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Hill-Rom Birthing Bed P3700

Hill-Rom Birthing Bed P3700

Create an account to install this asset package.

Maintenance Plans for Hill-Rom Birthing Bed Model P3700

Integrate maintenance plans directly into your work orders in MaintainX.

Air System Control P.C. Board Assembly Removal

Check mark

Set the brake/steer pedal to the brake position

Check mark

Ensure that the bed is out of the Trend-Like position

Check mark

Using the hilow function, raise the bed to the high position

Check mark

Using the head function, raise the head section to the high position

Check mark

SHOCK HAZARD: Unplug the unit from its power source. Failure to do so could result in personal injury or equipment damage

Check mark

Unplug the bed from its power source

Check mark

Remove the bottom motor cover (refer to procedure 4.2)

Check mark

Identify and disconnect all wiring connectors (A) from the air system control P.C. board (B) (see figure 4-27 on page 4-57)

Check mark

Using the phillips head screwdriver, remove the screw (C) that secures the air system control board (B) to the air system bracket (D)

Run this procedureArrow right

Air System Control P.C. Board Assembly Replacement

Check mark

Installation of the replacement air system control P.C. board

Check mark

Are the wiring connectors firmly connected to the air system control P.C. board receptacles?

Check mark

Function Checks

Check mark

Did the Affinity® Three Birthing Bed pass the function checks?

Run this procedureArrow right

Air System Manifold Assembly Removal

Check mark

Remove the air system assembly (refer to procedure 4.20)

Check mark

Disconnect the air hoses from the manifold assembly (A) (see figure 4-26 on page 4-55)

Check mark

Identify and disconnect the wiring connectors (B) from the manifold assembly (A)

Check mark

Using the phillips head screwdriver, remove the two screws (C) that secure the manifold assembly (A) to the mounting plate (D)

Run this procedureArrow right

Auxiliary Outlet Assembly Removal

Check mark

SHOCK HAZARD: The voltage in the electrical system presents an electrical shock hazard. Perform standard electrical service procedures before attempting service within the P.C. board enclosure. Adhere to all electrical safety precautions when servicing the bed’s electrical system. Failure to do so could result in personal injury or equipment damage.

Check mark

Set the brake/steer pedal to the brake position.

Check mark

Ensure that the bed is out of the Trend-Like position.

Check mark

Using the head function, raise the head section to the high position.

Check mark

Using the hilow function, raise the bed to the high position.

Check mark

Using the foot function, lower the foot section to the low position.

Check mark

Remove the foot section from the bed. Refer to “Foot Section (Lift Off)” on page 4-42 or “Foot Section (Slide Off)” on page 4-44.

Check mark

SHOCK HAZARD: Unplug the unit from its power source. Failure to do so could result in personal injury or equipment damage.

Check mark

Unplug the bed from its power source, and engage the lockout control.

Run this procedureArrow right

Auxiliary Outlet Assembly Replacement

Check mark

Installation of the replacement auxiliary outlet assembly

Check mark

Is the wiring connector (A) firmly connected to the auxiliary transformer assembly (B)?

Check mark

Function Checks

Check mark

Did the Affinity® Three Birthing Bed pass the function checks?

Check mark

Sign off on the auxiliary outlet assembly replacement

Run this procedureArrow right

Parts for Hill-Rom Birthing Bed P3700

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

2 Oz M-1 Oil (Apply To Oilite® Bearings And Bushings)

8252 (100)

4 Ounce Lithium Grease

SA3351 (100)

Adhesive

39172 (3700)

Air Hose

4698008 (3700)

Air Hose

4698031 (3700)

2 Oz M-1 Oil (Apply To Oilite® Bearings And Bushings)

8252 (100)

4 Ounce Lithium Grease

SA3351 (100)

Adhesive

39172 (3700)

Air Hose

4698008 (3700)

Air Hose

4698031 (3700)

2 Oz M-1 Oil (Apply To Oilite® Bearings And Bushings)

8252 (100)

4 Ounce Lithium Grease

SA3351 (100)

Adhesive

39172 (3700)

Air Hose

4698008 (3700)

Air Hose

4698031 (3700)

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Hill-Rom

Explore Other Assets