MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ
Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model MXZ-4C36NAHZ

Integrate maintenance plans directly into your work orders in MaintainX.

4-Way Valve Coil Replacement

Check mark

Removing the 4-way valve coil

Check mark

Service panel removed

Check mark

Upload a photo of the removed service panel

Check mark

4-way valve coil fixing screw (M5 × 7) removed

Check mark

4-way valve coil removed

Check mark

Connector 21S4 (green) on the multi controller circuit board disconnected

Check mark

Sign off on the 4-way valve coil replacement

Run this procedureArrow right

4-Way Valve Replacement

Check mark

Upload Photo 1 of the service panel and top panel removal

Check mark

Upload Photo 5 of the electrical parts box removal

Check mark

Upload Photo 4 and 7 of the valve bed removal

Check mark

Upload Photo 4 of the cover panel (front) removal

Check mark

Upload Photo 4 of the cover panel (rear) removal

Check mark

Upload Photo 4 of the side panel (R) removal

Check mark

Upload Photo 10 of the 4-way valve coil removal

Check mark

Refrigerant recovered without spreading in the air?

Check mark

Welded part of 4-way valve removed?

Run this procedureArrow right

Accumulator Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Upload Photo 1

Check mark

Service panel removed

Check mark

Top panel removed

Check mark

Front cover panel removed

Check mark

Back cover panel removed

Check mark

Side panel (R) removed

Check mark

Upload Photo 5

Check mark

Electrical parts box removed

Run this procedureArrow right

Base Heater Replacement

Check mark

Upload Photo 1 after removing the service panel

Check mark

Upload Photo 1 after removing the top panel

Check mark

Fan grille detached after removing 4 fixing screws (5 × 12)

Check mark

Upload Photo 1 after detaching the fan grille

Check mark

Propeller detached after removing a nut (for right handed screw of M6)

Check mark

Upload Photo 2 after detaching the propeller

Check mark

Check all connectors removed from multi controller circuit board

Check mark

Upload Photo 4 after pulling out the disconnected wire from the electrical parts box

Check mark

Wire clamps on the side of the motor support and separator loosened

Run this procedureArrow right

Bypass Valve Coil And Bypass Valve Replacement

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Remove the cover panel (front)

Check mark

Remove the cover panel (rear)

Check mark

Remove the side panel (R)

Check mark

Remove the bypass valve coil fixing screw (M4 × 6)

Check mark

Remove the bypass valve coil by sliding the coil upward

Check mark

Disconnect the connector SV1 (gray) or SV2 (blue) on the multi controller circuit board in the electrical parts box

Check mark

Remove the electrical parts box

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-4C36NAHZ

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type, Hermetic Compressor - 2,8 KW

ANB33FJSMT

Inverter Starter Type, Hermetic Compressor - 2,8 KW

ANB33FJSMT

Inverter Starter Type, Hermetic Compressor - 2,8 KW

ANB33FJSMT

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets