MaintainX Asset Hub logo
EnterprisePricing
Genie

Genie Lift Mast AWP-30S

Need answers fast?
Explore the manual using AI.

Genie Lift Mast AWP-30S
Genie Lift Mast AWP-30S

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Genie Lift Mast AWP-30S

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Genie Lift Mast AWP-30S

Genie Lift Mast AWP-30S

Create an account to install this asset package.

Maintenance Plans for Genie Lift Mast Model AWP-30S

Integrate maintenance plans directly into your work orders in MaintainX.

Air Filter/Regulator Canister Check

Check mark

Check the air filter/regulator canister for any water accumulation

Check mark

Is water visible in the canister?

Check mark

If water is visible, proceed to the next step. If not, the procedure is complete.

Check mark

Loosen the drain plug at the bottom of the canister and allow the water to drain out

Check mark

Tighten the drain plug

Check mark

Sign off on the air filter/regulator canister check

Run this procedureArrow right

Air Line Lubricator Oil Level Check

Check mark

Is the platform fully lowered?

Check mark

Measure the oil level in the lubricator canister

Check mark

The oil level must be within 1/2 inch / 12.7 mm from the top of the lubricator canister.

Check mark

Is the oil level within the specified range?

Check mark

If not, proceed to the next step.

Check mark

Upload a photo of the lubricator canister before adding oil.

Check mark

To add oil, remove the oil lubricator canister from the lubricator base and fill with oil.

Check mark

Upload a photo of the lubricator canister after adding oil.

Check mark

Install the canister back onto the lubricator base.

Run this procedureArrow right

Battery Charging

Check mark

To Charge Battery

Check mark

1 Open the battery pack lid to access the battery.

Check mark

2 Remove the battery vent caps and check the battery acid level. If necessary, add only enough distilled water to cover the plates. Do not overfill prior to the charge cycle.

Check mark

3 Replace the battery vent caps.

Check mark

4 Be sure that the DC output cord is properly connected to the battery.

Check mark

Black to negative, red to positive.

Check mark

5 Connect the battery charger to a grounded AC circuit.

Check mark

6 The charger will turn off automatically when the battery is fully charged.

Check mark

7 Check the battery acid level when the charge cycle is complete. Replenish with distilled water to the bottom of the fill tube. Do not overfill.

Run this procedureArrow right

Battery Check

Check mark

Warning: Contact with hot or live circuits could result in death or serious injury. Remove all rings, watches and other jewelry.

Check mark

Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water.

Check mark

Protective clothing and eye wear worn?

Check mark

Battery vent caps removed?

Check mark

Battery acid level

Check mark

Replenished with distilled water to the bottom of the battery fill tube?

Check mark

Vent caps installed?

Check mark

Sign off on the battery check

Run this procedureArrow right

Function Test

Check mark

Setup

Check mark

Position the machine on a firm surface directly below the desired work area

Check mark

Connect to the appropriate power source

Check mark

Insert the key and turn to platform control

Check mark

Pull out the red Emergency Stop button to the on position at the ground controls

Check mark

Twist to release the red Emergency Stop button at the platform controls

Check mark

Select an outrigger and slide it into a base socket until the outrigger lock pin snaps into place. Adjust the outrigger to level the machine and raise the base casters slightly off the ground. Level the machine using only the outriggers

Check mark

Check the interlock display lights at the ground controls. Confirm that the corresponding light is on

Check mark

Repeat this procedure for each of the remaining outriggers

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Genie

Explore Other Assets