MaintainX Asset Hub logo
EnterprisePricing
GEA

GEA Plate-Forming Machine CRM-600

Need answers fast?
Explore the manual using AI.

GEA Plate-Forming Machine CRM-600
GEA Plate-Forming Machine CRM-600

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for GEA Plate-Forming Machine CRM-600

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

GEA Plate-Forming Machine CRM-600

GEA Plate-Forming Machine CRM-600

Create an account to install this asset package.

Maintenance Plans for GEA Plate-Forming Machine Model CRM-600

Integrate maintenance plans directly into your work orders in MaintainX.

2000 Hourly Press Block Seal Replacement

Check mark

Warning!:

Check mark

- Do not attempt to use the machine unless you have read and understood all the information in the safety chapter and you are sure of your ability to use the machine safely

Check mark

- Do not attempt to use the machine unless you know how to stop it in an emergency as described under emergency stop in the safety chapter.

Check mark

Important conditions for safe operation without problems are: - accurate, continuous inspections

Check mark

- following all safety instructions.

Check mark

Warning!:

Check mark

- Switch off and lock the main switch before cleaning.

Check mark

Warning!: Do not change the alignment of the guiding of the guiding blocks.

Check mark

Press block:

Run this procedureArrow right

40 Hourly / 1 Daily Plates Maintenance

Check mark

Warning: Switch off and lock the main switch before inspection and maintenance work. Wait at least two minutes after switching off before carrying out repair work on electrical components.

Check mark

Inspect the form plate for cracks.

Check mark

Caution: Dispose of a cracked form plate. Never install a cracked form plate in the machine.

Check mark

Inspect all plates for scratches, burrs, grooves and sharp edges.

Check mark

Check the following

Check mark

Action to be taken

Check mark

Sign off on the plates maintenance

Run this procedureArrow right

40 Hourly / 1 Daily Tooling Set Cleaning

Check mark

Warning: Do not attempt to clean the machine unless you have read and understood all the first aid procedures that apply to your workspace and to the cleaning products that will be used

Check mark

If there is any safety instruction or procedure that you do not understand, do not clean this machine. Contact a supervisor and arrange for proper training on the cleaning of the machine

Check mark

Cleaning the machine without understanding and following all the safety instructions and procedures could lead to serious injury to yourself or others.

Check mark

Switch off and lock the main switch before cleaning.

Check mark

Cover the control panel prior to cleaning.

Check mark

Never spout directly at electrical components, bearings and chains.

Check mark

Always wear the acquired protective clothing

Check mark

Take care not to slip on the wet or greasy floor. It is recommended to wear protective shoes.

Check mark

Always apply to the prescribed protective means. Refer to the label and the safety regulations on the package

Run this procedureArrow right

6000 Hourly Hydraulic Oil Tank Maintenance

Check mark

Warning: Do not attempt to use the machine unless you have read and understood all the information in the safety chapter and you are sure of your ability to use the machine safely

Check mark

Do not attempt to use the machine unless you know how to stop it in an emergency as described under emergency stop in the safety chapter.

Check mark

Important conditions for safe operation without problems are: accurate, continuous inspections and following all safety instructions.

Check mark

Warning: Switch off and lock the main switch before cleaning.

Check mark

Check for contamination

Check mark

Action: remove sludge

Run this procedureArrow right

40 Hourly Multi Former Maintenance

Check mark

Warning: Do not attempt to use the machine unless you have read and understood all the information in the safety chapter and you are sure of your ability to use the machine safely

Check mark

Warning: Do not attempt to use the machine unless you know how to stop it in an emergency as described under emergency stop in the safety chapter.

Check mark

Important conditions for safe operation without problems are: accurate, continuous inspections and following all safety instructions.

Check mark

Warning: Switch off and lock the main switch before cleaning. Refer to chapter 1: Safety. Avoid a mixture of different lubricants. Choose lubricants, adapted to the ambient temperature.

Check mark

Warning: Turn off the hydraulic unit before maintenance or repair tasks.

Check mark

Oil temperature hydraulic system: Temperature - Check

Check mark

Oil level outfeed conveyor drive unit: Level - Check

Check mark

Oil level outfeed conveyor drive unit: Add oil, if necessary

Check mark

Oil level outfeed conveyor drive unit: Search for leaks

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from GEA

Explore Other Assets