

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Fluke Digital Multimeter 289
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Meter Case Maintenance
Safety Precautions
Remove test leads and any input signals before opening the case or replacing the battery or fuses.
Install only specified batteries or fuses for this product.
Place the uncovered Meter assembly on a protective surface to avoid unintended circuit shorting.
Opening the Meter Case
Disconnect test leads from any live source.
Turn the Meter off.
Remove the test leads from the input terminals.
Use a flat-blade screwdriver to turn the battery door fastener counterclockwise to unlock position.
Battery Replacement
Preparation
Turn off the meter
Remove test leads from the input terminals
Battery Replacement
Use a standard-blade screwdriver to unlock the battery door
Remove the battery door
Replace the batteries, observing proper polarity
Replace the battery door
Secure the battery door by locking the fastener
Fuse Replacement
Safety Precautions
Remove test leads and any input signals before replacing the battery or fuses.
Ensure only specified fuses and batteries are installed to prevent damage or injury.
Fuse Replacement Procedure
Turn the meter off and remove test leads from the input terminals.
Use a standard-blade screwdriver to turn the battery door fastener to the unlock position and remove the battery door.
Gently pry one end of the fuse loose and lift it out of the fuse contacts.
Install only Fluke specified replacement fuses with the correct amperage, voltage, and interrupt ratings.
Replace the battery door and secure it by turning the battery door fastener to the lock position.
Digital Multimeter Cleaning
Case Cleaning
Wipe the case with a damp cloth and mild detergent
Ensure no abrasives, isopropyl alcohol, or solvents are used
Safety Precautions
Ensure no water is allowed inside the case to avoid electrical shock or damage
Ensure no solvents are applied to the Meter to avoid damaging the housing
Terminal Cleaning
Turn the Meter off and remove all test leads
Shake out any dirt from the terminals
Access the parts list for your equipment in MaintainX.
Fluke-287-2004-01, Skin, Padxfer
2798418
Fluke-28X-2001, Case Top
2578178
Fluke-28X-2002, Case Bottom
2578184
Fluke-28X-2501, Mask, LCD, Padxfer
2760673
Fluke-28X-2006, Shield, Upper
2578252
Fluke-287-2004-01, Skin, Padxfer
2798418
Fluke-28X-2001, Case Top
2578178
Fluke-28X-2002, Case Bottom
2578184
Fluke-28X-2501, Mask, LCD, Padxfer
2760673
Fluke-28X-2006, Shield, Upper
2578252
Fluke-287-2004-01, Skin, Padxfer
2798418
Fluke-28X-2001, Case Top
2578178
Fluke-28X-2002, Case Bottom
2578184
Fluke-28X-2501, Mask, LCD, Padxfer
2760673
Fluke-28X-2006, Shield, Upper
2578252
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













