MaintainX Logo
EnterprisePricing
Daikin

Daikin Oil Cooling Unit AKZ328

Need answers fast?
Explore the manual using AI.

Daikin Oil Cooling Unit AKZ328
Daikin Oil Cooling Unit AKZ328

The Daikin Oil Cooling Unit AKZ328 is a high-performance industrial cooling solution designed for efficient temperature management in various applications. Known for its reliability and advanced technology, this unit ensures optimal cooling performance while minimizing energy consumption.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Oil Cooling Unit AKZ328

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Oil Cooling Unit AKZ328

Daikin Oil Cooling Unit AKZ328

Create an account to install this asset package.

Maintenance Plans for Daikin Oil Cooling Unit Model AKZ328

Integrate maintenance plans directly into your work orders in MaintainX.

2 Weekly Air Filter Maintenance

Check mark

• Be sure to wash the air filter with water at 40˚C or lower temperature every two weeks.

Check mark

• If the air filter is clogged with dust, the wind volume reduces, resulting in capacity deterioration. Also, the compressor’s protection device is activated, hindering smooth operation. Furthermore, it causes power consumption increase.

Check mark

• Operating the unit without the air filter causes a fault.

Check mark

• To remove the air filter, hold the bottom of the filter with both hands, and push it up while warping it forward.

Check mark

NOTE! If the air filter is clogged, the cooling capacity deteriorates, resulting in excess power consumption. Clean the air filter periodically to save power consumption.;

Run this procedureArrow right

1 Daily Oil Cooling Unit Maintenance

Check mark

• Oil pollution causes a fault or shortened service life of the pump. Use thorough caution about oil pollution to maintain the pollution degree at NAS10 or lower level.

Check mark

• Keep a normal oil level in the oil tank. Make sure that the oil does not contain air bubbles.

Check mark

• Clean inside of the oil tank periodically.

Check mark

• Make sure that the main machine oil piping is not blocked (fully closed).

Check mark

• Make sure that the oil piping has no oil leak.

Check mark

• Make sure that the power supply voltage is within the following range:

Check mark

50 Hz...........200 V ±10%

Check mark

60 Hz...........200/220 V ±10%

Check mark

• Make sure that the compressor, fan and oil pump do not abnormally sound during operation.

Run this procedureArrow right

6 Monthly Suction Strainer Cleaning

Check mark

• Clean the suction strainer every six months.

Check mark

• Clean to prevent the pump flow rate from being reduced by dust clogging.

Check mark

• Clean to prevent abnormal sound caused by cavitation.;

Run this procedureArrow right

Oil Cooling Unit Maintenance

Check mark

1. Condenser

Check mark

• If the condenser becomes extremely dirty, clean it with a brush, air blower, etc.

Check mark

* (When cleaning the condenser fins, wear gloves. Otherwise, you may be injured by the sharp edges.)

Check mark

2. Exterior

Check mark

• Wipe the exterior surface with a dry cloth. Never splash water over it.

Check mark

• To clean the exterior, do not use a brush, polish powder, acid, solvent (benzine etc.) or hot water. Using such substances causes the paint to peel off.;

Run this procedureArrow right

Parts for Daikin Oil Cooling Unit AKZ328

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Machine Temperature Tuning Thermistor (5 m)

AKZ8–OP–A5

Oil Temperature Control Thermistor (5 m)

AKZ8–OP–Y5

Communication Board

AKZ8–OP–CS

Machine Temperature Tuning Thermistor (10 m)

AKZ8–OP–K10

Oil Temperature Control Thermistor (10 m)

AKZ8–OP–Y10

Machine Temperature Tuning Thermistor (5 m)

AKZ8–OP–A5

Oil Temperature Control Thermistor (5 m)

AKZ8–OP–Y5

Communication Board

AKZ8–OP–CS

Machine Temperature Tuning Thermistor (10 m)

AKZ8–OP–K10

Oil Temperature Control Thermistor (10 m)

AKZ8–OP–Y10

Machine Temperature Tuning Thermistor (5 m)

AKZ8–OP–A5

Oil Temperature Control Thermistor (5 m)

AKZ8–OP–Y5

Communication Board

AKZ8–OP–CS

Machine Temperature Tuning Thermistor (10 m)

AKZ8–OP–K10

Oil Temperature Control Thermistor (10 m)

AKZ8–OP–Y10

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets