MaintainX Logo
EnterprisePricing
Daikin

Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

Need answers fast?
Explore the manual using AI.

Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B
Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

Create an account to install this asset package.

Maintenance Plans for Daikin 4-Zone Outdoor Heat Pump Model 4MKS58E3V1B

Integrate maintenance plans directly into your work orders in MaintainX.

Four Way Valve Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Before working, make sure that the refrigerant gas is empty in the circuit.

Check mark

Be sure to apply nitrogen replacement when heating up the brazed part.

Check mark

The cooling only models have no four way valve coil.

Check mark

Warning: Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.

Check mark

Warning: If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)

Check mark

Caution: From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.

Check mark

Cautions for restoration

Check mark

1. Restore the piping by nonoxidation brazing.

Run this procedureArrow right

Outdoor Fan / Fan Motor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Preparation: Remove the outer panels and plates. Remove the electrical box.

Check mark

Remove the 2 screws of the fan motor fixing plate.

Check mark

Remove the fan motor fixing plate. When reassembling, fit the lower hooks.

Check mark

Nut size: M6

Check mark

When reassembling, align the mark of the outdoor fan with the D-cut section of the motor shaft.

Check mark

Remove the nut and remove the outdoor fan.

Check mark

Open the 2 hooks and release the fan motor lead wire.

Check mark

When reassembling, put the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan.

Run this procedureArrow right

PCB Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Remove the service monitor PCB.

Check mark

1 External appearance

Check mark

2 Remove the screw of the terminal board and open it.

Check mark

3 Disconnect the connectors [S52] [S102] from the service monitor PCB.

Check mark

4 Unfasten the upper hook and pull the service monitor PCB upward to remove.

Check mark

2. Remove the main PCB.

Check mark

[AC1] [AC2] : for power supply [S10] : for transmission

Check mark

1 Disconnect the connectors for the terminal board on the right side.

Run this procedureArrow right

Compressor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the terminal cover.

Check mark

Disconnect the compressor lead wires.

Check mark

Detach the overload protector.

Check mark

Remove the putty.

Check mark

Remove the 2 nuts.

Check mark

Before working, make sure that the refrigerant gas is empty in the circuit.

Check mark

Be sure to apply nitrogen replacement when heating up the brazed part.

Check mark

Heat up the brazed part of the discharge side and disconnect the part (a).

Run this procedureArrow right

Distributor Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1 Remove the putty.

Check mark

Before working, make sure that the refrigerant gas is empty in the circuit.

Check mark

Be sure to apply nitrogen replacement when heating up the brazed part.

Check mark

Warning: Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.

Check mark

Warning: If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)

Check mark

Caution: From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.

Check mark

Cautions for restoration

Check mark

1. Restore the piping by nonoxidation brazing.

Run this procedureArrow right

Parts for Daikin 4-Zone Outdoor Heat Pump 4MKS58E3V1B

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Silicon Grease

1172698

Silicon Grease

1172698

Silicon Grease

1172698

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets