Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Daikin Air Conditioner RWEQ264TAYCU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Maintenance
1 Management of water quality
The plate-type heat exchanger has a structure that does not permit dismantling and cleaning, or replacing any parts. Please pay attention carefully to the quality of water to be used for the plate-type heat exchanger in order to prevent corrosion and sticking of scale
The water to be used for the plate-type heat exchanger should have at least the quality as specified in the table of "4.4.1 Water quality requirements" on page 15
When using any corrosion prevention agent, scale depressant agent, etc., such agent should have no corrosive features against stainless steel and copper
2 Management of condenser water flow rate
If the condenser water flow rate is not enough, it will result in freezing damage to the plate-type heat exchanger. Check for any clogging of the strainer, any air being caught, any reduction in the flow rate due to failure of the circulation pump by measuring the temperature and pressure differences at the inlet and outlet ports of the plate-type heat exchanger
If the aged difference in the temperature or pressure has increased beyond the proper range, the flow rate should have decreased. Stop the operation and remove the cause before restarting the operation
3 Steps to be taken if a freeze-protection device is activated
If the freeze-protection device is activated during operation, be sure to remove the cause before restarting the operation. If the freeze-protection device has been once activated, a partial freezing has already occurred
1 Yearly Maintenance
Preventing electrical hazards when maintaining and servicing the system
Clean the plate heat exchanger
The refrigerant recovery operation;
Access the parts list for your equipment in MaintainX.
Refnet Header
KHRP26M72H9
Strainer
-
Piping accessory bag
-
Cool/Heat Change Over PCB
BRP2A81
Refnet Joint
KHRP26M73TU9
Refnet Header
KHRP26M72H9
Strainer
-
Piping accessory bag
-
Cool/Heat Change Over PCB
BRP2A81
Refnet Joint
KHRP26M73TU9
Refnet Header
KHRP26M72H9
Strainer
-
Piping accessory bag
-
Cool/Heat Change Over PCB
BRP2A81
Refnet Joint
KHRP26M73TU9
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX