Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carrier Container Refrigeration Unit 69NT40-511-13
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Filter-Drier Replacement
Preparation
Pump unit down to 0 psi
Filter-Drier Replacement
Replace filter-drier
Evacuation and Valve Operation
Evacuate the unit as per section 6.5
Open the manual liquid line valve
Post-Operation Inspection
Inspect for moisture in system after unit is in operation
Evaporator Coil Replacement
Preparation
Pump unit down
Turn power OFF and remove power plug
Panel and Wiring Disconnection
Remove screws securing the panel covering the evaporator section
Disconnect the defrost heater wiring
Disconnect the sensor from the coil
Coil Removal
Remove middle coil support
Controller/Datacorder Maintenance
Handling of Controller/DataCORDER
Ensure all safety precautions are followed
Obtain a grounding wrist strap and a static dissipation mat
Disconnect and secure power to the unit
Place strap on wrist and attach the ground to an unpainted metal area on the refrigeration unit frame
Carefully remove the Controller/DataCORDER and place it on the static mat
Is the refrigeration unit service completed?
Re-install the module into the refrigeration unit after service work
Removing and Installing the Controller/DataCORDER Module
Suction Solenoid Valve Maintenance
Replacing the Coil
Disconnect leads by unplugging the connector.
Remove snap cap or locknut and lift off coil.
Verify coil type, voltage and frequency of old and new coil.
Replacing Valve Internal Parts -- Alco
Pump down the unit.
Remove snap cap and coil.
Remove enclosing tube collar using installation/removal tool.
Check plunger for restriction due to:
AMBS/DTS Sensors Check
Preparation
Turn unit OFF and disconnect power supply
Refer to section 6.27 for removal of the Controller module
Sensor Identification and Measurement
Identify the sensor to be checked
Measure the ohms resistance using the plug connector marked 'EC'
Record the ohms resistance readings as per Table 6-1
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX