Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carrier Container Refrigeration Unit 69NT40-511-6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Sensors Replacement
Preparation
Turn unit power OFF and disconnect power supply.
Remove and save any cover over wiring and probe holder, if present.
Defective Sensor Removal
Cut cable 5 cm (2 inches) from shoulder of defective sensor and discard the defective probe only.
Save cap and grommet assembly for reuse on the replacement probe.
Cable Preparation
Cut one wire of existing cable 41 mm (1-5/8 inches) shorter than the other wire.
Cut one replacement sensor wire (opposite color) back 41 mm (1-5/8 inches).
Thermostatic Expansion Valve
Minor Periodic Maintenance
Ensure excess capillary tube is secured to the power head assembly and wrapped with 'Presstite'.
Ensure thermal bulb is tightly secured to the suction line and wrapped with 'Presstite'.
Removing Expansion Valve
Pump down the unit per section 6.3.
Remove insulation (Presstite) from expansion valve bulb and power assembly and then remove thermal bulb from the suction line.
Loosen flare nut and disconnect equalizing line from expansion valve.
Remove capscrews and lift off power assembly and remove cage assembly.
Check for foreign material in valve body.
Evaporator Coil Replacement
Preparation
Pump unit down
Turn power OFF and remove power plug
Panel and Wiring Removal
Remove screws securing the panel covering the evaporator section (upper panel)
Disconnect the defrost heater wiring
Disconnect the sensor from the coil
Coil Removal
Remove middle coil support
Recording Thermometer Bulb Temperature Check
Preparation
Select the method for temperature stabilization
Unit Running Method
Set the unit's set point to 0°C (32°F)
Allow the unit to pull down to 0°C (32°F)
Enter the number of compressor ON-OFF cycles observed
Is the temperature stabilized at 0°C (32°F) as verified by the resistance thermometer?
Enter the temperature indicated by the thermometer when the compressor cycles off
Does the thermometer reading differ from 0°C (32°F) by more than 0.6°C (1°F)?
Refrigerant Charging
Checking the Refrigerant Charge
Set the controller set point to -25°C (-13°F)
Ensure the suction modulation valve is fully open
Connect the gauge manifold to the compressor service valves
Select the type of condenser
Enter the compressor discharge pressure
Is the refrigerant level within the sight glass boundaries?
Adding Refrigerant to System (Full Charge)
Evacuate unit and leave in deep vacuum
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX