Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carrier Container Refrigeration Unit 69NT40-511-12
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Refrigerant Charging
Preliminary Checks
Ensure compliance with local environmental laws and regulations
Set the controller set point to -25°C (-13°F)
Ensure the suction modulation valve is fully open
Verify container temperature is approximately 1.7°C (35°F) or -17.8°C (0°F)
Checking Refrigerant Level
Connect the gauge manifold to the compressor service valves
Select unit type for refrigerant level check
Enter the compressor discharge pressure
Evaporator Coil Replacement
Preparation
Pump unit down
Turn off power and remove power plug
Panel and Wiring Disconnection
Remove screws securing the panel covering the evaporator section
Disconnect the defrost heater wiring
Disconnect the sensor from the coil
Coil Removal
Remove middle coil support
High Pressure Switch Replacement
Preparation
Turn unit start-stop switch OFF
Frontseat both suction and discharge service valves to isolate compressor
Remove the refrigerant from the compressor
Switch Removal
Disconnect wiring from defective switch
Remove the high pressure switch by turning counterclockwise
Switch Installation
Verify new switch settings
Thermostatic Expansion Valve
Minor Periodic Maintenance
Ensure excess capillary tube is secured to the power head assembly and wrapped with 'Presstite'.
Ensure thermal bulb is tightly secured to the suction line and wrapped with 'Presstite'.
Removing Expansion Valve
Pump down the unit per section 6.3.
Remove insulation (Presstite) from expansion valve bulb and power assembly and then remove thermal bulb from the suction line.
Loosen flare nut and disconnect equalizing line from expansion valve.
Remove capscrews and lift off power assembly and remove cage assembly.
Check for foreign material in valve body.
Recording Thermometer Element Replacement
Turn unit OFF and disconnect power source
Remove upper back panel and bulb clamps securing bulb to unit
Remove two flange screws from recording thermometer and feed capillary and element through the unit
Push replacement bulb end and capillary through the unit
Fill slots with silastic (RTV432, Dow Corning)
Attach bulb clamps tightly to bulb
Connect element flange to recorder ensuring hub of flange faces out to fit into the hole in instrument case
Rezero the recorder
Install inlet air grille and upper panel
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX