MaintainX, an Autodesk company
EnterprisePricing
Carrier

Carrier Container Refrigeration Unit 69NT40-511-16

Need answers fast?
Explore the manual using AI.

Carrier Container Refrigeration Unit 69NT40-511-16
Carrier Container Refrigeration Unit 69NT40-511-16

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Carrier Container Refrigeration Unit 69NT40-511-16

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Carrier Container Refrigeration Unit 69NT40-511-16

Carrier Container Refrigeration Unit 69NT40-511-16

Create an account to install this asset package.

Maintenance Plans for Carrier Container Refrigeration Unit Model 69NT40-511-16

Integrate maintenance plans directly into your work orders in MaintainX.

Sensors Check

Check mark

Preparation

Check mark

Prepare an ice-water bath at 0°C (32°F)

Check mark

Ensure the ohmmeter is calibrated and ready for use

Check mark

Sensor Placement and Initial Check

Check mark

Place the sensor in the ice-water bath

Check mark

Check air temperature/data readout on the control panel

Check mark

Is the air temperature/data readout 0°C (32°F)?

Check mark

Power Down and Module Access

Check mark

Turn unit OFF

Run this procedureArrow right

AMBS/DTS Sensors Replacement

Check mark

Power Disconnection

Check mark

Turn unit power OFF

Check mark

Disconnect power supply

Check mark

Wire Preparation

Check mark

Cut wires to 25.4 cm (10 inches) from the back of the mounting stud of the defective sensor and discard.

Check mark

Cut one of the two wires 25.4 mm (1.0 inch) shorter than the other wire.

Check mark

Cut one replacement sensor wire back 25.4 mm (1.0 inch).

Check mark

Strip back insulation on all wiring 6.35mm (1/4 inch).

Check mark

Crimping and Soldering

Run this procedureArrow right

Filter-Drier Replacement

Check mark

Preparation

Check mark

Pump unit down to 0 psi

Check mark

Filter-Drier Replacement

Check mark

Replace filter-drier

Check mark

Evacuation and Valve Operation

Check mark

Evacuate the unit as per section 6.5

Check mark

Open the manual liquid line valve

Check mark

Post-Operation Inspection

Check mark

Inspect for moisture in system after unit is in operation

Run this procedureArrow right

Recording Thermometer Bulb Temperature Check

Check mark

Preparation

Check mark

Select the method for temperature stabilization

Check mark

Unit Running Method

Check mark

Set the unit's set point to 0°C (32°F)

Check mark

Allow the unit to pull down to 0°C (32°F)

Check mark

Enter the number of compressor ON-OFF cycles observed

Check mark

Record the temperature indicated by the thermometer when the compressor cycles off

Check mark

Does the temperature differ from 0°C (32°F) by more than 0.6°C (1°F)?

Check mark

Unit Off Method

Run this procedureArrow right

Saginomiya Recording Thermometer Maintenance

Check mark

Battery Maintenance

Check mark

Open door and remove chart nut and platen.

Check mark

Push voltage indicator test switch. Is the voltage indicator in the red or white zone?

Check mark

Replace battery if voltage indicator points to the red or white zone.

Check mark

Calibration

Check mark

Install new chart on platen.

Check mark

Place recorder bulb in ice bath for 10 minutes.

Check mark

Rotate the chart by hand and check the stylus indicated temperature.

Check mark

Is adjustment required?

Run this procedureArrow right

Parts for Carrier Container Refrigeration Unit 69NT40-511-16

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Rupture Disc 1

14-00215-03

Rupture Disc 2

14-00215-04

Manifold Gauge

07-00294-00

Vacuum Pump

07-00176-01

Simpson Meter

07-00013

Rupture Disc 1

14-00215-03

Rupture Disc 2

14-00215-04

Manifold Gauge

07-00294-00

Vacuum Pump

07-00176-01

Simpson Meter

07-00013

Rupture Disc 1

14-00215-03

Rupture Disc 2

14-00215-04

Manifold Gauge

07-00294-00

Vacuum Pump

07-00176-01

Simpson Meter

07-00013

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Carrier

Explore Other Assets