Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carrier Container Refrigeration Unit 69NT40-511-16
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Sensors Check
Preparation
Prepare an ice-water bath at 0°C (32°F)
Ensure the ohmmeter is calibrated and ready for use
Sensor Placement and Initial Check
Place the sensor in the ice-water bath
Check air temperature/data readout on the control panel
Is the air temperature/data readout 0°C (32°F)?
Power Down and Module Access
Turn unit OFF
AMBS/DTS Sensors Replacement
Power Disconnection
Turn unit power OFF
Disconnect power supply
Wire Preparation
Cut wires to 25.4 cm (10 inches) from the back of the mounting stud of the defective sensor and discard.
Cut one of the two wires 25.4 mm (1.0 inch) shorter than the other wire.
Cut one replacement sensor wire back 25.4 mm (1.0 inch).
Strip back insulation on all wiring 6.35mm (1/4 inch).
Crimping and Soldering
Filter-Drier Replacement
Preparation
Pump unit down to 0 psi
Filter-Drier Replacement
Replace filter-drier
Evacuation and Valve Operation
Evacuate the unit as per section 6.5
Open the manual liquid line valve
Post-Operation Inspection
Inspect for moisture in system after unit is in operation
Recording Thermometer Bulb Temperature Check
Preparation
Select the method for temperature stabilization
Unit Running Method
Set the unit's set point to 0°C (32°F)
Allow the unit to pull down to 0°C (32°F)
Enter the number of compressor ON-OFF cycles observed
Record the temperature indicated by the thermometer when the compressor cycles off
Does the temperature differ from 0°C (32°F) by more than 0.6°C (1°F)?
Unit Off Method
Saginomiya Recording Thermometer Maintenance
Battery Maintenance
Open door and remove chart nut and platen.
Push voltage indicator test switch. Is the voltage indicator in the red or white zone?
Replace battery if voltage indicator points to the red or white zone.
Calibration
Install new chart on platen.
Place recorder bulb in ice bath for 10 minutes.
Rotate the chart by hand and check the stylus indicated temperature.
Is adjustment required?
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX