Carrier Container Refrigeration Unit 69NT40-511-11
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
High Pressure Switch Check
Safety Precautions
Ensure a pressure regulator is used with the nitrogen cylinder
Ensure no oxygen is present near the refrigeration system
Preparation
Remove the high pressure switch as outlined in section 6.12.1
Connect ohmmeter or continuity light across switch terminals
Pressure Test
Connect hose to a cylinder of dry nitrogen
Open cylinder valve
AMBS/DTS Sensors Replacement
Power Disconnection
Turn unit power OFF
Disconnect power supply
Wire Preparation
Cut wires to 25.4 cm (10 inches) from the back of the mounting stud of the defective sensor and discard.
Cut one of the two wires 25.4 mm (1.0 inch) shorter than the other wire.
Cut one replacement sensor wire back 25.4 mm (1.0 inch).
Strip back insulation on all wiring 6.35mm (1/4 inch).
Crimping and Soldering
Resistance Thermometer Check
Prepare Ice Water Mixture
Fill thermos container with ice cubes or chips
Fill voids between ice with plain water
Stir the solution until it registers 0 to 0.3°C (32 to 32.5°F) on a laboratory thermometer
Check Resistance Thermometer Accuracy
Immerse the resistance thermometer in the 0°C (32°F) solution
Is the recommended length of the check probe immersed?
Does the resistance thermometer register 0°C (32°F)?
Post-Check Adjustments
AMBS/DTS Sensors Check
Turn unit OFF
Disconnect power supply
Refer to section 6.27 for removal of the Controller module
Identify the plug connector marked 'EC' connected to the Controller module
Locate the wires marked AMBS or DTS
Measure the ohms resistance using the pins of the plug
Record the ohms resistance readings
Compressor Oil Level Check
Initial Operation
Operate the unit in cooling mode for at least 20 minutes
Is there any foaming of the oil in the front oil sight glass after 20 minutes of operation?
Oil Level Check
Turn unit off to check the oil level
Is the oil level between the bottom to one-eighth level of the sight glass?
Oil Adjustment
Select the action based on oil level
Adding Oil with Compressor in System
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX