Carrier Container Refrigeration Unit 69NT40-511-5
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
AMBS/DTS Sensors Replacement
Power Disconnection
Turn unit power OFF
Disconnect power supply
Wire Preparation
Cut wires to 25.4 cm (10 inches) from the back of the mounting stud of the defective sensor and discard.
Cut one of the two wires 25.4 mm (1.0 inch) shorter than the other wire.
Cut one replacement sensor wire back 25.4 mm (1.0 inch).
Strip back insulation on all wiring 6.35mm (1/4 inch).
Crimping and Soldering
AMBS/DTS Sensors Check
Preparation
Turn unit OFF and disconnect power supply
Refer to section 6.27 for removal of the Controller module
Sensor Identification and Measurement
Identify the sensor type to be checked
Measure the ohms resistance using the plug connector marked 'EC'
Refer to Table 6-1 for resistance readings
Refrigerant Charging
Checking the Refrigerant Charge
Ensure compliance with environmental laws
Set the controller set point to --25_C (--13_F)
Ensure the suction modulation valve is fully open
Measure container temperature
Units with Receiver
Connect the gauge manifold to the compressor discharge and suction service valves
Partially block the condenser coil inlet air to raise compressor discharge pressure to approximately 12 kg/cm@ (175 psig)
Is the refrigerant level between the sight glasses?
Refrigerant Leak Check
WARNING
Ensure no mixing of refrigerants with air for leak testing.
Leak Detection
Use R-134a electronic leak detector for finding leaks.
Test joints with soapsuds for large leaks.
System Charging and Leak Check
Charge the system with refrigerant to build up pressure between 2.1 to 3.5 kg/cm² (30 to 50 psig).
Remove refrigerant cylinder.
Leak-check all connections.
Compressor Replacement
Removal of Old Compressor
Remove the protective guard from lower section of the unit.
Remove all refrigerant using a refrigerant recovery system.
Locate the compressor junction box and remove wiring.
Disconnect wiring from compressor terminals and remove compressor junction box.
Remove bolts from service valve flanges.
Remove compressor plate mounting bolts.
Remove compressor and mounting plate.
Remove high pressure switch (HPS) from compressor and check operation of switch.
Access the parts list for your equipment in MaintainX.
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
Rupture Disc 1
14-00215-03
Rupture Disc 2
14-00215-04
Manifold Gauge
07-00294-00
Vacuum Pump
07-00176-01
Simpson Meter
07-00013
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX