MaintainX Asset Hub logo
EnterprisePricing
A.O. Smith

A.O. Smith Copper Boiler DW-1810

Need answers fast?
Explore the manual using AI.

A.O. Smith Copper Boiler DW-1810
A.O. Smith Copper Boiler DW-1810

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for A.O. Smith Copper Boiler DW-1810

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

A.O. Smith Copper Boiler DW-1810

A.O. Smith Copper Boiler DW-1810

Create an account to install this asset package.

Maintenance Plans for A.O. Smith Copper Boiler Model DW-1810

Integrate maintenance plans directly into your work orders in MaintainX.

Initial Circulating Pump Lubrication

Check mark

Pre-Lubrication Checks

Check mark

Verify water conditions

Check mark

Is the circulating pump properly sized for the application?

Check mark

Lubrication Process

Check mark

Oil the three oil cups as instructed on the oil tube supplied with the unit

Check mark

Add 2 or 3 teaspoonfuls of No. 20 non-detergent motor oil in bearing oil cups

Check mark

Add 10 or 12 drops of No. 20 non-detergent motor oil in motor oil cups

Check mark

Post-Lubrication Checks

Check mark

Was the lubrication process completed successfully?

Run this procedureArrow right

Heat Exchanger Deposits Removal

Check mark

Preparation

Check mark

Remove cover panel from far side of water connections

Check mark

Expose the heat exchanger return bends

Check mark

Return Bends Removal

Check mark

Remove return bends using a 9/16" deep socket ratchet

Check mark

Inspection and Cleaning

Check mark

Inspect tubes to ensure they are free of scale and deposits

Check mark

Are the tubes scaled?

Check mark

Remove deposits with a stiff wire brush or mechanical tube cleaner to bare metal

Run this procedureArrow right

4 Monthly Circulating Pump Lubrication

Check mark

Preparation

Check mark

Ensure the circulating pump is properly sized for the application

Check mark

Check water hardness and system pressure drop

Check mark

Verify temperature rise across the boiler

Check mark

Lubrication Process

Check mark

Oil the three oil cups (2 on the motor, 1 on the pump) as instructed on the oil tube

Check mark

Add 2 or 3 teaspoonfuls of No. 20 non-detergent motor oil in bearing oil cups

Check mark

Add 10 or 12 drops of No. 20 non-detergent motor oil in motor oil cups

Check mark

Post-Lubrication Check

Run this procedureArrow right

2 Monthly Boiler Deliming

Check mark

Preparation

Check mark

Ensure water softening equipment is operational

Check mark

Is there a change of approximately 5°F in the normal temperature rise through the boiler?

Check mark

Inspection

Check mark

Inspect the interior of the inlet/outlet manifold through the pressure relief valve tapping for lime build-up

Check mark

Deliming Process

Check mark

Obtain UN•LIME from dealer or distributor

Check mark

Read the instructions on the label of the UN•LIME container

Check mark

Ensure all necessary equipment is made of copper or brass

Run this procedureArrow right

Main Burners Cleaning

Check mark

Preparation

Check mark

Shut off all gas to the unit

Check mark

Shut off all electric to the unit

Check mark

Burner Tray Removal

Check mark

Disconnect union assembly

Check mark

Disconnect pilot line connection at main burner

Check mark

Slide tray out of cabinet

Check mark

Burner Cleaning

Check mark

Remove main burners from unit

Run this procedureArrow right

Parts for A.O. Smith Copper Boiler DW-1810

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

UN•LIME(Deliming Solvent, 1 Gallon)

4763

UN•LIME(Deliming Solvent, 5 Gallons)

4813

Two Tank Manifold Kit

170354

Three Tank Manifold Kit

170355

Tank Fitting 2" (50 Mm)

94447

UN•LIME(Deliming Solvent, 1 Gallon)

4763

UN•LIME(Deliming Solvent, 5 Gallons)

4813

Two Tank Manifold Kit

170354

Three Tank Manifold Kit

170355

Tank Fitting 2" (50 Mm)

94447

UN•LIME(Deliming Solvent, 1 Gallon)

4763

UN•LIME(Deliming Solvent, 5 Gallons)

4813

Two Tank Manifold Kit

170354

Three Tank Manifold Kit

170355

Tank Fitting 2" (50 Mm)

94447

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from A.O. Smith

Explore Other Assets