

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Advantage Temperature Controller SRV-1675
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pump Seal Replacement
Preparation
Disengage process operations and relieve all system pressure.
Disengage main power supply and verify the Power light on the display is 'off'.
Accessing the Pump
Remove the lift-off access panel and set aside.
Remove the necessary panels to gain access to the pump motor.
Draining and Disconnecting
Drain machine by removing the pump casing drain plug.
Remove the three motor wire leads from the motor wiring terminals and map the wire terminal locations.
Heater Contactor and Pump Motor Starter Inspection
Heater Contactor Inspection
Inspect heater contactor for signs of wear or pitting
Is the heater contactor in good condition?
Pump Motor Starter Inspection
Inspect pump motor starter for signs of wear or pitting
Is the pump motor starter in good condition?
Safety Precautions
Ensure all power sources are turned off before inspection
Wear appropriate personal protective equipment (PPE)
Sensor Probe Maintenance
Reconnection Procedure
Unplug the service connection
Shake out the water from the connection
Replug the service connection
Did the yellow Alert icon disappear?
Replacement Procedure
Stop process operations as described in section 3.4 of the manual
Ensure all process pressure is relieved and pressure gauges read '0' pressure
Drain the unit by removing the pump casing drain plug
Cooling Valve Maintenance
Preparation
Disengage process operations according to the procedure outlined in section 3.4.
Ensure coolant pressure gauge reads '0'.
Shut off water system flow.
Disengage main power supply following all lockout/tagout procedures.
Access Solenoid Valve
Remove or open any access cover panel and set aside to gain access to the make-up solenoid valve.
Disassemble Solenoid Valve
Remove the 4 retaining screws to disassemble the solenoid valve.
Initial Equipment Check
Unboxing and Initial Inspection
Unbox the unit before accepting delivery
Check for visible damage
Is there any visible damage?
Documentation of Damage
Document any evident damage on the delivery receipt
Did you refuse the shipment due to damage?
Upload photographs of any suspected damage
Post-Inspection Procedures
Access the parts list for your equipment in MaintainX.
Case 119, Iron, 1.25x1.25 with Integral Tanks
771640
Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks
771641
Impeller 503, Composite, 4.18", 0.5 HP
4310560
Impeller 503, Composite, 4.34", 0.75 HP
4310561
Impeller 503, Composite, 4.50", 1.0 HP
4310562
Case 119, Iron, 1.25x1.25 with Integral Tanks
771640
Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks
771641
Impeller 503, Composite, 4.18", 0.5 HP
4310560
Impeller 503, Composite, 4.34", 0.75 HP
4310561
Impeller 503, Composite, 4.50", 1.0 HP
4310562
Case 119, Iron, 1.25x1.25 with Integral Tanks
771640
Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks
771641
Impeller 503, Composite, 4.18", 0.5 HP
4310560
Impeller 503, Composite, 4.34", 0.75 HP
4310561
Impeller 503, Composite, 4.50", 1.0 HP
4310562
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













