MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Controller SRG-1665

Need answers fast?
Explore the manual using AI.

Advantage Temperature Controller SRG-1665
Advantage Temperature Controller SRG-1665

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Controller SRG-1665

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Controller SRG-1665

Advantage Temperature Controller SRG-1665

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Controller Model SRG-1665

Integrate maintenance plans directly into your work orders in MaintainX.

Heater Replacement

Check mark

Preparation

Check mark

Disengage operations and ensure all system pressure is relieved and the unit’s pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Access and Drainage

Check mark

Remove the lift-off access panel and set aside.

Check mark

Drain machine by removing the pump casing drain plug.

Check mark

Heater Disconnection

Check mark

Remove heater’s junction box cover to locate wiring connections.

Check mark

Note the wiring connections for correct reinstallation.

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Preparation

Check mark

Shut down unit operations according to section 3.4 in the manual

Check mark

Ensure proper lock-out procedures are followed

Check mark

Confirm system pressure is eliminated and the unit’s pressure gauges read '0' pressure

Check mark

Pressure Switch Removal

Check mark

Drain unit by removing the pump casing drain plug

Check mark

Remove the capillary connection from the cooling cylinder to the pressure switch

Check mark

Remove the brass elbow mounted on the pressure switch

Check mark

Disconnect the electrical connections to the pressure switch

Run this procedureArrow right

Sensor Probe Maintenance

Check mark

Reconnection Procedure

Check mark

Unplug the service connection

Check mark

Shake out the water from the connection

Check mark

Replug the service connection

Check mark

Did the yellow Alert icon disappear?

Check mark

Replacement Procedure

Check mark

Stop process operations as described in section 3.4 of the manual

Check mark

Ensure all process pressure is relieved and pressure gauges read '0' pressure

Check mark

Drain the unit by removing the pump casing drain plug

Run this procedureArrow right

Voltage Change

Check mark

Pre-Conversion Consultation

Check mark

Consult with Advantage Service Department to determine if unit can be converted. Record details of the consultation.

Check mark

Record Serial Number and call 317-887-0729 for assistance.

Check mark

Typical Conversions

Check mark

Select the conversion type

Check mark

Consult factory for other power conversions and record details.

Check mark

Items Requiring Replacement or Rewiring

Check mark

Identify items for replacement or rewiring

Check mark

Field Voltage Changeover Procedure

Run this procedureArrow right

Cooling Valve Maintenance

Check mark

Preparation

Check mark

Disengage process operations and verify all system pressure is relieved and the unit’s pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Remove the lift-off access panel and set aside.

Check mark

Disconnect the valve wiring harness.

Check mark

Remove the AVTTM valve’s drip cover.

Check mark

Motor/Gearbox Assembly Service

Check mark

Remove the 2 mounting screws securing the motor/gearbox assembly.

Check mark

Carefully separate the motor/gearbox from the attached coupling from the valve assembly.

Run this procedureArrow right

Parts for Advantage Temperature Controller SRG-1665

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Valve

8764939

Case 119, Iron, 1.25x1.25 with Integral Tanks

771640

Case 119S, Stainless SS304, 1.25x1.25 with Integral Tanks

771641

Impeller 503, Composite, 4.18", 0.5 HP

4310560

Impeller 503, Composite, 4.34", 0.75 HP

4310561

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets